Setting Up Service Provider Connectivity
"
8-20
If management needs to be set up between a service provider's customer and its
network operations center (NOC), a non-multiplexed DLCI must be configured to
carry management data between the customer's central site and the NOC
console. This requires that a frame relay discovered DLCI needs to be modified.
This is because all auto-configured network DLCIs are configured as multiplexed
DLCIs.
Procedure
To set up NOC management:
1. Select DLCI Records on the network interface:
Configuration → Network → DLCI Records
2. Select Modify. The Modify DLCI Record for DLCI Number? prompt
appears.
3. Select the DLCI that will be used by pressing the spacebar until the correct
DLCI number appears, then select it.
4. Change the DLCI Type from Multiplexed to Standard.
The DLCI in connections. Update DLCI usage as follows:
prompt appears.
5. Select Yes at the Delete EDLCI Connections and Make a Mgmt
Only PVC option.
6. Select Yes at the prompt.
PVC connections for the selected DLCI are broken, the Port-1 DLCI mapped
to this network DLCI and the embedded management DLCI (EDLCI) are
deleted, and the selected DLCI will be reconfigured as a management PVC
using the Node IP Address.