5-6 Ohm Measurement

1) Push the " Power switch " ( 3-2, Fig. 1 ) to " On " position.
On = 1, Off = 0
2) Select the " Ohm Switch " ( 3-5, Fig. 1 ).
3) Connect red test lead to " V/Ohm Terminal " ( 3-17, Fig. 1 ).
and black test lead to " COM Terminal " ( 3-18, Fig. 1 ).
4) If the resistance being measured is connected to a circuit,
turn off power to circuit being tested and discharge all
capacitors.
5) Connect test lead probes into circuit (resistance) under
test.
6) Read resistance value on digital display.
5-7 AC Watt, VA, Whr measurement, current input
cooperate with CT ( current transformer )
Other measurement procedures are same as the 5-1, 5-2,
except :
1) Wire connection as following, ref. Fig. 3
Voltage :
" V Terminal " ( 3-17, Fig. 3 ) & " COM terminal "
( 3-18, Fig. 3 )
Current :
Current transformer output connect to the " 10A
Terminal " ( 3-19, Fig. 3 ) & " COM terminal "
( 3-18, Fig. 3 )
2) Select the CT type, 100/5A or 1000/5A by push the
" Current Mode Button " ( 3-12, Fig. 1). The LCD will
show the marker " CT 100/5A ", " CT 1000/5A " when
the CT type is selected.