6 Operation
Operation
6.1 Charging the Battery
Before the first operation, the main battery should be fully charged by using the included USB charging
cable. As long as the battery is charging the red LED (3) will light solid red. After the battery is fully charged
the red LED (3) turns off. A full recharge of the battery takes approx. 4 to 5 hours.
To charge the battery via USB follow the instructions below:
1.
Remove the USB protection clip (9) from the device.
2.
Connect the device to the USB port of a computer or to the USB power adapter (accessories).
3.
As long as the battery is charging, the red LED (3) lights solid red.
4.
After the battery is fully charged the red LED (3) turns off.
6.2 Device Reset
To reset the ID PM ECCO+ press and hold the keys 1, 2, 3 and 4 (see chapter 4 Product Description on
page 9) for 5 seconds.
 NOTE:
By reset the device loses its timestamp. Before continuing to use it you must synchronize the
time settings by connecting the ID PM ECCO+ with the Master Setup. The time thereby will be
automatically synchronized with the system time of your PC.
Specific configuration settings and data will not be lost by the reset.
6.3 Configuration
To set the alternative configuration mode follow the steps below:
1.
Switch off the device.
2.
Press and hold keys 4 and 5 until a beep sound appears (this may take a few seconds).
3.
Connect the ID PM ECCO+ to a computer via USB.
4.
The device will be mounted as a removable drive "SCANNDY".
5.
Open the file "config.ini" or use the Universal Configurator to modify the settings.
6.
Press button 3 (trigger) until a beep sound appears.
7.
The device restarts with the new settings.
The ID PM ECCO+ config.ini file contains the most common device settings. For information about the
configuration for options like Bluetooth, Wi-Fi, HF and UHF RFID as well as barcode configuration please
refer to the document Config_ini.pdf.