Under Counter (UC-24) Series
Door Assembly (Models UC-24R, UC-24RO)
NOTE:
If removing a model UC-24R or UC-24RO from
its installation, an anti-tip bracket and a countertop
bracket may have been used to make a solid installa-
tion.
After pulling unit approximately 6" out from its installa-
tion
(See Figure 7-68):
1. Remove door closer.
2. Open door.
3. Extract screws from top cabinet hinge.
4. Lean door assembly away from unit slightly, then lift
door hinge pin out of the bottom cabinet hinge.
Component Access/Removal
Figure 7-68. Door Removal
7-27
#7003933 - Revision B - November, 2007
Cabinet Hinge
Mounting Screws