Pressure Control Knob - Graco 16H960 Operation, Parts, Repair

Protective coating hand-held
Table of Contents

Advertisement

Pressure Control Knob

Removal
1. Engage trigger lock and put prime/pressure relief
valve in UP position to relieve pressure.
ti19350a
2. Loosen two set screws (34) from pressure control
knob and remove knob.
30
ti19347a
34
ti19620a
Installation
NOTE: Inlet valve must be fully installed before outlet
valve can be installed.
1. Make sure prime/pressure relief valve is in UP posi-
tion. Use a thin screwdriver or allen wrench to turn
outlet valve counter-clockwise until it touches inlet
ball. DO NOT TIGHTEN. Outlet valve should only
be threaded until inlet ball does not move when
touched.
ti19347a
2. Install pressure control knob. Turn knob fully coun-
ter-clockwise ("0" setting will line up with red dot).
Torque set screws (34) to 40 in-lb (4.5 N•m).
ti19620a
Repair
ti19616a
34
ti19351a
3A2308A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

16n65416n92716n65516n656

Table of Contents