Adjusting Pressure - Graco 16H960 Operation, Parts, Repair

Protective coating hand-held
Table of Contents

Advertisement

Adjusting Pressure

NOTE: To reduce overspray and extend battery life,
always spray at lowest pressure that results in an
acceptable spray pattern.
1. Put the pressure relief valve UP to relieve pressure.
ti19347a
2. Turn pressure control knob:
Clockwise to INCREASE pressure, or
Counter-clockwise to DECREASE pressure.
THIN
MATERIAL
0 1 2 3 4 5 6 7 8 9 10 11
3. Dial in pressure by spraying material on a scrap
material.
10
ti19372a
THICK
MATERIAL
ti19407a
4. Start with dial at "1" and gradually increase in incre-
ments of "1" or less until desired spray pattern is
achieved. Put pressure relief handle in UP position
to turn pressure control knob, then return handle to
DOWN position to spray.
ti19353a
ti19408a
Operation
ti19409a
3A2308A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

16n65416n92716n65516n656

Table of Contents