Q Cable Specifications; Enphase Connector Ratings - enphase IQ 7 Series Installation And Operation Manual

Micros with en4 bulkhead
Table of Contents

Advertisement

Q Cable Specifications

Specification
Voltage rating
Voltage withstand test (kV/1min)
Max DC conductor resistance (20ºC) (Ω/km)
Insulation resistance (20ºC)
System temperature range (ambient)
Cable temperature rating
Cable rating
Certification
Flame test rating
Cable conductor insulator rating
Environmental protection rating
UV resistance
Compliance
Conductor size
Maximum loop size
Flat cable dimensions
Sealing cap dimensions
Cable connector dimensions

Enphase Connector Ratings

Enphase Connectors on the cable assemblies in the following table have a maximum current of 20 A, a
maximum OCPD of 20 A, and maximum ambient temperature of -40° to +79° C (-40° to +174.2° F) and
are rated for disconnection under load.
Part Number
840-00387
840-00388
840-00389
860-00311
860-00315
860-00312
41
IQ 7 / IQ 7+ / IQ 7X / IQ 7A with EN4 Bulkhead Installation and Operation
600V
AC 3.0
5.433
≥20M (Ω/km)
-40ºC to +65ºC (-40ºF to 149ºF)
90ºC Dry / 90ºC Wet
DG
UL 3003, TC-ER equivalent
FT4
THHN/THWN-2
IEC 60529 IP67 NEMA 6
720h
RoHS, OIL RES I, CE, UV Resistant, combined UL for Canada
and United States
12 AWG
12 cm (4.75 ")
6 mm x 9.5 mm (0.2" x 0.37")
38.6 mm x 20 mm (1.5" x 0.7")
20 mm x 1.1 mm x 6.5 mm (0.7" x 0.04" x 0.25")
Q-12-10-240
Q-12-17-240
Q-12-20-200
ECA-EN4-S22
ECA-EN4-S22-L
ECA-EN4-FW
© 2020 Enphase Energy Inc. All rights reserved.
Value
Model
250 VAC
250 VAC
250 VAC
80 VDC
80 VDC
80 VDC
Maximum Voltage
141-00047-01

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Iq 7Iq 7xIq 7a