enphase IQ Encharge-3T-1P-NA Quick Install Manual

enphase IQ Encharge-3T-1P-NA Quick Install Manual

Hide thumbs Also See for IQ Encharge-3T-1P-NA:

Advertisement

Q U I C K I N S T A L L G U I D E
Install the Enphase IQ
To install the Enphase IQ
Battery 3T system or IQ
TM
in this guide. Safety warnings are listed on the back of this guide. These instructions are not meant to be a complete explanation of how to design and install
an energy storage system. All installations must comply with national and local electrical codes and standards. Only qualified electricians shall install, trou-
bleshoot, or replace the IQ
Battery 3T or IQ
TM
The IQ
Battery system includes the Enphase IQ
TM
production and home energy consumption. The IQ
when it is abundant and used when scarce. IQ
installed at the site.
Five unique installation
scenarios are shown:
Whole home backup with IQ
System
TM
Controller as service entrance and
PV combiner connected to IQ
TM
System Controller. This is the preferred
configuration for back up of the entire main
load panel. This configuration supports up
to an 80A breaker for the PV circuit and an
80A breaker for battery storage.
NOTE:
1. For M215/M250 connection to Enphase
Energy System, refer tech brief at
https://
enphase.com/en-us/storage-m-series
2. M series microinverters require Gateway-S
metered.
Whole home backup with IQ
System
TM
Controller as service entrance and PV
combiner connected to main load panel.
This is the preferred configuration when you
back up the entire main load panel, and the
size of the PV combiner circuit is more than
80A. In this configuration, the PV combiner
circuit connection space in IQ
System
TM
Controller is left vacant. When existing PV
combiner circuits are connected to the main
load panel, and you want to add battery
storage to the system, you can keep the PV
combiner connected to the main load panel
and connect only the battery storage to IQ
System Controller.
Partial home backup with main load panel
as service entrance and PV combiner
connected to IQ
System Controller. When
TM
PV circuits breaker size is less than 80A,
this is the preferred configuration for partial
home backup with subpanel.
(Models Encharge-3T-1P-NA and Encharge-10T-1P-NA)
Battery 10T system and the Enphase wall-mount bracket, read and follow all warnings and instructions
TM
Battery 10T.
TM
Battery(ies) with integrated Enphase IQ
TM
Battery system senses when it is optimal to charge or discharge the battery so that energy is stored
TM
Battery systems are capable of providing backup power when an Enphase IQ
TM
TM
© 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ
App, and other trademarks or service names are trademarks of Enphase Energy, Inc. Data subject to change. Rev09- 07-13-2022
Battery System
TM
Microinverters. The Enphase IQ
TM
Battery, IQ
TM
Gateway measures PV
TM
System Controller is
TM
(optional)
(optional)
(optional)
Gateway, IQ
combiner, IQ
Microinverter, Enphase Installer
TM
TM
TM

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IQ Encharge-3T-1P-NA and is the answer not in the manual?

Questions and answers

Summary of Contents for enphase IQ Encharge-3T-1P-NA

  • Page 1 © 2022 Enphase Energy. All rights reserved. Enphase, the Enphase logo, IQ Battery, IQ Gateway, IQ combiner, IQ Microinverter, Enphase Installer App, and other trademarks or service names are trademarks of Enphase Energy, Inc. Data subject to change. Rev09- 07-13-2022...
  • Page 2 (ies). Total weight for the 3T, including the Battery Battery base unit, cover and wall mount bracket, is 48.8 kg (107.6 lbs). Battery G ) Install the PV system and the IQ Combiner as directed by the Enphase installation manuals.
  • Page 3: Installation

    (107.6 lbs), while the total weight for IQ Battery 10T including G ) Select a location where you can interconnect to the Enphase IQ the mounting bracket and cover add up to 152.1 kg (335.3 lbs). System Controller.
  • Page 4 Install the IQ Battery 3T (single width) or IQ Battery Battery 10T — triple-width bracket 10T (triple width) wall mount bracket A ) Place the middle wall-mount bracket on the wall so that the mounting Follow the instruction below for the bracket style you are installing. holes of the bracket align with the center of the stud, and the mounting holes on the left and right align with the adjacent studs.
  • Page 5 Battery. Use the conduit openings provided to connect the conduit and pass the wires through them. Note that if an Enphase IQ System Controller is in line-of-sight, the breaker can service as a disconnect. WARNING! Risk of equipment damage. Do not modify or rewire the pre-installed wiring or bonding connections in the field wiring compartment.
  • Page 6 WARNING: Complete the Enphase IQ System Controller and En- G ) Gently arrange all the wires and connectors inside the field wiring phase Combiner installations before turning the DC switch(es) ON.
  • Page 7 Cover and energize the system (continued) B ) Turn ON the AC power first (branch circuit protection) and then turn ON the DC switches of the IQ Batteries. NOTE: Do NOT leave the IQ Battery unit’s DC switch in the ON position for any extended period of time (such as overnight or for more than 24 hours) unless IQ Battery is commissioned (communicating with IQ...
  • Page 8: Operation

    Battery unit. Further, Enphase reserves the right to refuse to provide support in connection with any such use and disclaims any and all liability arising out of Enphase’s provision of, or refusal to provide, support for your IQ Battery device in such circumstances.
  • Page 9: Safety Instructions

    CTs. The IQ Gateway is required for operation of the IQ from the Enphase System and turn the DC connect switch to the off position so Battery(ies). Earlier versions of the Enphase Gateway communications gateway are that charging/discharging stops.

This manual is also suitable for:

Iq encharge-10t-1p-na

Table of Contents