INSTALLATION MANUAL
PROFIL100EC
Illuminated Mullion Weatherproof Keypad with remote Electronics
Default values
- Without codes.
- Illumination time: 10 seconds.
- relay release time: 1 second.
- code length: 5-digits.
- Master code: 1 2 3 4 5.
- Programming security time :
120 secondes.
- code length for sub master code:
Version 1 relay
(Group 1) = AB,
Version 2 relays
(Group 2) = 13.
Audible signal:
- The buzzer indicates different
audible signals.
- It can be turned off by cutting
A. Reset master code
and user codes
1. Enter the master code twice
(1 2 3 4 5 default value master code).
2 beeps are emitted to confirm entry
in programming mode.
2. Press A6 to reset the Master Code
and the User codes.
- One beep is emitted.
- Press on A and B to confirm reset
of all memory of the keypad.
- Wait for two beeps.
- The master code is restored to its default
value 1 2 3 4 5 and all the User codes
are deleted from the keypad.
- Once the reset is completed then the keypad
returns to a stand-by operating mode.
OR
1. Cut the power. Place the jumper on P2.
2. Put the power back.
- Wait approximately 3 seconds.
- Two beeps are emitted to confirm reset
of the keypad.
- remove P2 jumper.
the ST1 wire on the remote
electronics.
- 1 short beep: Keypad powered.
- 1 long beep: Data computing
in programming or access
granted.
- 2 short beeps: Enter or Exit
from programming.
- 4 short beeps:
data computing error.
Code length
- The master code and the User
codes can be of 4 or 5-digits
in length.
- All the keypad keys can be used
to program a code.
B. Setting code length
1. Enter the master code twice.
2. Press A4 to program the code length.
3. Press A5 to modify the master code.
4. Press B to exit from
4 beeps indicate a data computing error.
- The master code and the Pin code
can be of 4 or 5-digits code.
- The master code cAN NOT
be used as a PIN code
(User Pin code).
- To delete a specific User pin Code
replace it by 0 0 0 0 if code
length is 4-digits format or
replace it by 0 0 0 0 0 if the
code is in 5-digits format.
P2 jumper:
reset master code and user
codes
P3 jumper:
Modification of individual
code by the user
- The master code is restored to its default
value 1 2 3 4 5 and all the User codes
are deleted from the keypad.
(1 2 3 4 5 default value master code).
2 beeps are emitted to confirm entry
in programming mode.
- One beep is emitted.
- Press 4 or 5 for the digit code.
- One beep is emitted to confirm
programming of the code length.
- One beep is emitted.
- Enter the new 4 or 5-digits master code.
- One beep is emitted to confirm
programming of the new master code.
programming mode.
2 beeps are emitted to confirm that the
keypad is in stand-by operating mode.