Heating capacity: 20% to 100% capacity Smart mode Intelligent optimisation As standard Fast heating Silence mode Heating capacity: 20% to 80% capacity Use at night Sound level: 3dB (A) lower than Smart mode. Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
1.4.2. When moving the heat pump, do not lift the water union. This will damage the titanium heat exchanger. 1.4.3. Do not obstruct the air inlet or outlet of the heat pump. Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
Page 6
1.4.6. If you detect any abnormal noises, odours, smoke or leaks from the heat pump, immediately switch off the power supply and contact your local dealer. Do not attempt to repair the heat pump yourself. Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
Page 7
1.4.8. Please disconnect the heat pump from the power supply during electrical storms. 1.4.9. Please note that following codes are not failures. CODES No water flow Anti-freezing reminder Out of the operating range Insufficient water flow or pump blocked Power abnormal Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
After you turn on the heat pump, the fan will start to run in 3 minutes. In another 30 seconds, the compressor will start to run. • During heating, the icon will display. Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
Page 9
“ and “ “ buttons for 5 seconds to start compulsory defrosting. (Note: the interval between compulsory defrosting should be more than 30 minutes). • The heating light will flash when heat pump is in compulsory or auto defrosting. WIFI setting Please refer to page 21. Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
When using the heat pump under 2°C, make sure there is always water flow. Unscrew the water union of inlet pipe to let the water flow out. When the water in machine freezes in winter season, the titanium heat exchanger may be damaged. Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
The values indicated are valid under ideal conditions: Pool covered with an isothermal cover. Related parameters are subject to adjustment periodically for technical improvement without further notice. For details please refer to nameplate. Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
When storing or moving the heat pump, please ensure the unit remains in an upright position at all times. 4.2. When moving the heat pump, do not lift the water union. This will damage the titanium heat exchanger. Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
ATTENTION 5.1. NOTICE BEFORE INSTALLATION 5.1.1. Plumbing connections must be made with solid PVC pipe. Usage of flexible PVC pipe is not recommended. Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
This increases the operating time by 3% to 5%. Do not obstruct the air inlet or outlet of the heat pump. The efficiency may be reduced or even stopped. Side Discharge 800mm From Sides 500mm From Top 400mm From Back 2500mm From Front Discharge Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
Page 15
Independent System HEAT PUMP - BACK SOLAR PUMP NON RETURN VALVE 3 WAY VALVE In-line System HEAT PUMP - BACK FILTER FILTER PUMP CHLORINATOR NON RETURN VALVE 3 WAY VALVE Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
Page 16
Adjusting the Bypass HEAT PUMP - BACK FILTER FILTER PUMP CHLORINATOR NON RETURN VALVE 3 WAY VALVE Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
Page 17
Operation without a bypass or with improper bypass adjustment may result in suboptimal heat pump operation and possible damage to the heat pump. Failure to observe this ATTENTION instruction will void the warranty. Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
Page 18
When the heat pump is running, condensation will occur and drain from the bottom of the unit. This is completely normal. However, consideration should be made for how to drain the condensation away. Drainage nozzle and pipe are supplied. Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
Page 19
NOTE: The above data is adapted to power cord ≤ 10m .If power cord is >10m, wire diameter must be increased. The signal cable can be extended to 50m at most. Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
3 minutes, in another 30 seconds, the compressor will start to run. After pool heat pump starts up, check for any abnormal noise from the heat pump. Check the temperature setting Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
When water inlet temperature ≥ 15°C or air temperature ≥ 1°C, heat pump will be powered off or on standby. If above solutions don’t work, please contact your installer with detailed information and your model number. ATTENTION Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
Inverter board overheat protection Current protection Cooling plate overheat protection Fan motor failure Power filter plate No-power protection PFC module over current protection Please contact your installer with detailed information and your model number. ATTENTION Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
8. WIFI SETTING APP Download Android mobile please download from iPhone please download from Account registration Registration by mobile number/Email Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
Page 24
Mobile number registration Aus +61 Create family Please set family name and choose the room of device Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
Page 25
Under WIFI setting status, press the for 5 seconds to clear pairing. Then follow step above for rebinding. Exit WIFI setting: during WIFI setting, press “ “ or “ “ to exit. Remarks: Please make sure the router is configured at 2.4G. Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
Page 26
Operation a) For heat pump with Heating function only Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
Page 27
Share devices to your family members After binding, if your family members also want to control the device. Please let your family members register the APP first, and then the administrator can operate as below: Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
Page 28
Then your family members can log in as below: Notice: 1. The weather forecast is just for reference. 2. APP is subject to updating without notice. Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
(d) in the case of other heat pump components, a two (2) year limited warranty from Supreme Solar Pty Ltd, 2/19 Enterprise Drive, Bundoora, Victoria, 3083 (Phone: (03) 9460 4200, Email: info@supremeheating.com.au); Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
Page 30
(g) by other abuse or misuse caused by the Purchaser or a third party. Subject to clause 9, any condition or warranty which would otherwise be implied in this agreement or in relation to the Product is hereby excluded. Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
Page 31
Supreme Solar Pty Ltd pool heating system (c) Governing law (paragraph 16): Victoria, Australia Consumer guarantee 18 This warranty is provided in addition to consumer guarantees and does not alter, limit or replace them. Heatseeker VortexE Inverter Heat Pump Installation & User Manual...
Need help?
Do you have a question about the HEATSEEKER VORTEXE and is the answer not in the manual?
Questions and answers