Supreme Heating HEATSEEKER VORTEXPRO Installation & User Manual

Supreme Heating HEATSEEKER VORTEXPRO Installation & User Manual

Inverter heat pump
Hide thumbs Also See for HEATSEEKER VORTEXPRO:

Advertisement

INSTALLATION & USER MANUAL
N A T I O N A L
1
Heatseeker VortexPro Inverter Heat Pump
Installation & User Manual

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the HEATSEEKER VORTEXPRO and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Supreme Heating HEATSEEKER VORTEXPRO

  • Page 1 INSTALLATION & USER MANUAL N A T I O N A L Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 2 QLD 4207 M: 0455 064 765 solarqld@supremeheating.com.au SA Office Wingfield SA 5013 M: 0437 947 375 solarsa@supremeheating.com.au WA Office Perth WA 6000 M: 0447 876 786 darren@supremeheating.com.au solar@supremeheating.com.au 1300 787 978 supremeheating.com.au Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 3: Table Of Contents

    INSTALLATION & USER MANUAL HEATSEEKER VORTEXPRO INVERTER HEAT PUMP Published October 2018 FOR USERS General information 1.1. Contents 1.2. Operating conditions and range 1.3. Advantages of different modes 1.4. Kind reminder Operations 2.1. Notice before using 2.2. Operation instructions 2.3.
  • Page 4: General Information

    Heating capacity: 20% to 100% capacity Smart mode Intelligent optimisation As standard Fast heating Silence mode Heating capacity: 20% to 80% capacity Use at night Sound level: 3dB (A) lower than Smart mode. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 5: Kind Reminder

    1.4.2. When moving the heat pump, do not lift the water union. This will damage the titanium heat exchanger. 1.4.3. Do not obstruct the air inlet or outlet of the heat pump. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 6 1.4.6. If you detect any abnormal noises, odours, smoke or leaks from the heat pump, immediately switch off the power supply and contact your local dealer. Do not attempt to repair the heat pump yourself. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 7 1.4.8. Please disconnect the heat pump from the power supply during electrical storms. 1.4.9. Please note that following codes are not failures. CODES No water flow Anti-freezing reminder Out of the operating range Insufficient water flow or pump blocked Power abnormal Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 8: Operations

    Turn on the heat pump and the fan will start to run after 3 minutes. In another 30 seconds, the compressor will start to run. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 9 (Note: the break between compulsory defrost needs to be more than 30 minutes.) The defrost symbol is on when machine is in compulsory defrost mode or auto defrost mode. Compulsory defrost will take the same amount of time as auto defrost. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 10: Daily Maintenance And Winterizing

    Unscrew the water union of inlet pipe to let the water flow out. When the water in machine freezes in winter season, the titanium heat exchanger may be damaged. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 11: Technical Specification

    The values indicated are valid under ideal conditions: Pool covered with an isothermal cover. Related parameters are subject to adjustment periodically for technical improvement without further notice. For details please refer to nameplate. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 12: Transportation

    When storing or moving the heat pump, please ensure the unit remains in an upright position at all times. 4.2. When moving the heat pump, do not lift the water union. This will damage the titanium heat exchanger. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 13: Installation And Maintenance

    ATTENTION 5.1. NOTICE BEFORE INSTALLATION 5.1.1. Plumbing connections must be made with solid PVC pipe. Usage of flexible PVC pipe is not recommended. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 14: Installation Instructions

    Do not obstruct the air inlet or outlet of the heat pump. The efficiency may be reduced or even stopped. Side Discharge 800mm From Sides 500mm From Top 400mm From Back 2500mm From Front Discharge Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 15 Independent System HEAT PUMP - BACK SOLAR PUMP NON RETURN VALVE 3 WAY VALVE In-line System HEAT PUMP - BACK FILTER FILTER PUMP CHLORINATOR NON RETURN VALVE 3 WAY VALVE Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 16 Adjusting the Bypass HEAT PUMP - BACK FILTER FILTER PUMP CHLORINATOR NON RETURN VALVE 3 WAY VALVE Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 17 Operation without a bypass or with improper bypass adjustment may result in suboptimal heat pump operation and possible damage to the heat pump. Failure to observe this ATTENTION instruction will void the warranty. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 18 When the heat pump is running, condensation will occur and drain from the bottom of the unit. This is completely normal. However, consideration should be made for how to drain the condensation away. Drainage nozzle and pipe are supplied. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 19 50Hz Distribution Box (Customer prepare) Swimming Pool Heat Pump Wiring Board Power Cord Power Supply Fuse 380V 50Hz Breaker Earthing For the detailed wiring diagram, please refer to Appendix 1. ATTENTION Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 20: Trial After Installation

    Check the electric wiring according to the electrical wiring diagram and earthing connection; Make sure that the main power is well connected; Check if there is any obstacle in front of the air inlet and outlet of the heat pump Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 21 3 minutes, in another 30 seconds, the compressor will start to run. After pool heat pump starts up, check for any abnormal noise from the heat pump. Check the temperature setting Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 22: Vortex Switch

    SB02 PLUG INTO 240V GPO ENSLAVEMENT FROM HEAT PUMP FLOW HEAT-PUMP FILTER OPTIONAL CIRCULATION PUMP POOL/SPA Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 23: Installation Instructions

    Potential free Dry Contact Power supply 230V ~ / 50Hz Control Wire Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 24: Trouble Shooting For Common Faults

    If above solutions don’t work, please contact your installer with detailed information and your model number. Don’t try to repair it yourself. Please don’t try to repair the heat pump by yourself to avoid any risk. ATTENTION Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 25: Error Codes

    Compressor running failure Inverter board over current protection Inverter board overheat protection Current protection Cooling plate overheat protection Fan motor failure Power filter plate No-power protection PFC module over current protection Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 26: Warranty Agreement

    (d) in the case of other heat pump components, a two (2) year limited warranty from Supreme Solar Pty Ltd, 2/19 Enterprise Drive, Bundoora, Victoria, 3083 (Phone: (03) 9460 4200, Email: info@supremeheating.com.au); Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 27 (g) by other abuse or misuse caused by the Purchaser or a third party. Subject to clause 9, any condition or warranty which would otherwise be implied in this agreement or in relation to the Product is hereby excluded. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 28 Supreme Solar Pty Ltd pool heating system (c) Governing law (paragraph 16): Victoria, Australia Consumer guarantee 18 This warranty is provided in addition to consumer guarantees and does not alter, limit or replace them. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 29 NOTES Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 30 NOTES Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 31 Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
  • Page 32 1300 787 978 supremeheating.com.au Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...

Table of Contents