INSTALLATION & USER MANUAL HEATSEEKER VORTEXPRO INVERTER HEAT PUMP Published October 2018 FOR USERS General information 1.1. Contents 1.2. Operating conditions and range 1.3. Advantages of different modes 1.4. Kind reminder Operations 2.1. Notice before using 2.2. Operation instructions 2.3.
Heating capacity: 20% to 100% capacity Smart mode Intelligent optimisation As standard Fast heating Silence mode Heating capacity: 20% to 80% capacity Use at night Sound level: 3dB (A) lower than Smart mode. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
1.4.2. When moving the heat pump, do not lift the water union. This will damage the titanium heat exchanger. 1.4.3. Do not obstruct the air inlet or outlet of the heat pump. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
Page 6
1.4.6. If you detect any abnormal noises, odours, smoke or leaks from the heat pump, immediately switch off the power supply and contact your local dealer. Do not attempt to repair the heat pump yourself. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
Page 7
1.4.8. Please disconnect the heat pump from the power supply during electrical storms. 1.4.9. Please note that following codes are not failures. CODES No water flow Anti-freezing reminder Out of the operating range Insufficient water flow or pump blocked Power abnormal Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
Turn on the heat pump and the fan will start to run after 3 minutes. In another 30 seconds, the compressor will start to run. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
Page 9
(Note: the break between compulsory defrost needs to be more than 30 minutes.) The defrost symbol is on when machine is in compulsory defrost mode or auto defrost mode. Compulsory defrost will take the same amount of time as auto defrost. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
Unscrew the water union of inlet pipe to let the water flow out. When the water in machine freezes in winter season, the titanium heat exchanger may be damaged. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
The values indicated are valid under ideal conditions: Pool covered with an isothermal cover. Related parameters are subject to adjustment periodically for technical improvement without further notice. For details please refer to nameplate. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
When storing or moving the heat pump, please ensure the unit remains in an upright position at all times. 4.2. When moving the heat pump, do not lift the water union. This will damage the titanium heat exchanger. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
ATTENTION 5.1. NOTICE BEFORE INSTALLATION 5.1.1. Plumbing connections must be made with solid PVC pipe. Usage of flexible PVC pipe is not recommended. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
Do not obstruct the air inlet or outlet of the heat pump. The efficiency may be reduced or even stopped. Side Discharge 800mm From Sides 500mm From Top 400mm From Back 2500mm From Front Discharge Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
Page 15
Independent System HEAT PUMP - BACK SOLAR PUMP NON RETURN VALVE 3 WAY VALVE In-line System HEAT PUMP - BACK FILTER FILTER PUMP CHLORINATOR NON RETURN VALVE 3 WAY VALVE Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
Page 16
Adjusting the Bypass HEAT PUMP - BACK FILTER FILTER PUMP CHLORINATOR NON RETURN VALVE 3 WAY VALVE Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
Page 17
Operation without a bypass or with improper bypass adjustment may result in suboptimal heat pump operation and possible damage to the heat pump. Failure to observe this ATTENTION instruction will void the warranty. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
Page 18
When the heat pump is running, condensation will occur and drain from the bottom of the unit. This is completely normal. However, consideration should be made for how to drain the condensation away. Drainage nozzle and pipe are supplied. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
Page 19
50Hz Distribution Box (Customer prepare) Swimming Pool Heat Pump Wiring Board Power Cord Power Supply Fuse 380V 50Hz Breaker Earthing For the detailed wiring diagram, please refer to Appendix 1. ATTENTION Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
Check the electric wiring according to the electrical wiring diagram and earthing connection; Make sure that the main power is well connected; Check if there is any obstacle in front of the air inlet and outlet of the heat pump Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
Page 21
3 minutes, in another 30 seconds, the compressor will start to run. After pool heat pump starts up, check for any abnormal noise from the heat pump. Check the temperature setting Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
If above solutions don’t work, please contact your installer with detailed information and your model number. Don’t try to repair it yourself. Please don’t try to repair the heat pump by yourself to avoid any risk. ATTENTION Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
Compressor running failure Inverter board over current protection Inverter board overheat protection Current protection Cooling plate overheat protection Fan motor failure Power filter plate No-power protection PFC module over current protection Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
(d) in the case of other heat pump components, a two (2) year limited warranty from Supreme Solar Pty Ltd, 2/19 Enterprise Drive, Bundoora, Victoria, 3083 (Phone: (03) 9460 4200, Email: info@supremeheating.com.au); Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
Page 27
(g) by other abuse or misuse caused by the Purchaser or a third party. Subject to clause 9, any condition or warranty which would otherwise be implied in this agreement or in relation to the Product is hereby excluded. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
Page 28
Supreme Solar Pty Ltd pool heating system (c) Governing law (paragraph 16): Victoria, Australia Consumer guarantee 18 This warranty is provided in addition to consumer guarantees and does not alter, limit or replace them. Heatseeker VortexPro Inverter Heat Pump Installation & User Manual...
Need help?
Do you have a question about the HEATSEEKER VORTEXPRO and is the answer not in the manual?