Nibe S1155 Installer Manual page 27

Ground source heat pump 1x230v
Hide thumbs Also See for S1155:
Table of Contents

Advertisement

1x230 V S1155-6
Max electric-
Max phase current L1(A)
al addition
(kW)
0.0
0.5
1.0
1.5
2.0
2.5
3.0
3.5
4.0
1
4.5
1
Factory setting
1x230 V, S1155-12
Max electric-
Max phase current L1(A)
al addition
(kW)
0.0
1.0
2.0
3.0
4.0
5.0
6.0
1
7.0
1
Factory setting
EMERGENCY MODE
When S1155 is put into emergency mode, the system
works as follows:
• S1155 prioritises heating production.
• Hot water is produced if possible.
• The immersion heater is stepped according to the
setting in menu 7.1.8.2 - Emergency mode.
• Fixed supply temperature if the system has no value
from the outdoor sensor (BT1).
You can activate the emergency mode both when S1155
is running and when it is switched off.
When the emergency mode is active, the status lamp
turns yellow.
To activate when S1155 is running: press and hold the
on/off button (SF1) for 2 seconds and select "emergency
mode" from the shutdown menu.
To activate when S1155 is switched off: press and hold
the on/off button (SF1) for 5 seconds. (Deactivate the
emergency mode by pressing once.)
NIBE S1155
2.2
4.3
6.5
8.7
10.9
13.0
15.2
17.4
19.6
4.3
8.7
13.0
17.4
21.7
26.1
30.4
Chapter 5 | Electrical connections
27