Label NEPTIS/LE Installation Manual

Label NEPTIS/LE Installation Manual

Swing door operator for one or two wings

Advertisement

SWING DOOR
GB
OPERATOR
for one or two wings
Installation
NEPTIS/LE
Manual
CD0356GB - NEPTIS/LE - Rel.1.0 - 03/2007

Advertisement

Table of Contents
loading

Summary of Contents for Label NEPTIS/LE

  • Page 1 SWING DOOR OPERATOR for one or two wings Installation NEPTIS/LE Manual CD0356GB - NEPTIS/LE - Rel.1.0 - 03/2007...
  • Page 2 Ilariuzzi 17/A- 43100 San Pancrazio Parmese. PARMA- ITALY Declares that: NEPTIS/LE actuator for swing doors 8 has been designed to be built into machinery or to be assembled with other devices so as to form machinery covered by Machine...
  • Page 3: Table Of Contents

    CONTENTS MECHANICAL SECTION page 1.0 ACTUATOR COMPONENTS “ 2.0 ARMS “ 3.0 GENERAL SAFETY RECOMMENDATIONS “ 4.0 MACHINE DIRECTIVES “ 5.0 INSTRUCTIONS FOR USE “ 6.0 HOW TO PREPARE AND FIX THE ACTUATOR “ 7.0 TECHNICAL DRAWINGS “ 8.0 ARM CONNECTIONS “...
  • Page 4: Mechanical Section

    MECHANICAL NEPTIS/LE SECTION...
  • Page 5: Actuator Components

    1.0 ACTUATOR COMPONENTS 1-Regulating dip-switches and potentiometers 5-Keypad board housing 2-Powering board and connections 6-Photocell board housing 3-Spring 7-Projecting pin 4-Spring preload reference 8-Spring locking screw 2.0 ARMS SLIDING ARM ARTICULATED ARM...
  • Page 6: General Safety Recommendations

    5.0 INSTRUCTIONS FOR USE The "NEPTIS/LE” actuator is suitable for continuous service. The maximum weight of the wing it drives depends on the actual wing itself, on the type of arm and on the type of fixing mechanism (POWER or SPEED).
  • Page 7: How To Prepare And Fix The Actuator

    The arm can be connected to either side of the mechanical body of the actuator. This means that the direction of the opening movement can be selected. The connection side of the arm is identified by the label on the mechanical body. This shows the opening direction of the pin. Bear in mind which type of arm (either sliding or articulated) and fixing method (on the wall or wing) will be used.
  • Page 8: Technical Drawings

    7.0 TECHNICAL DRAWINGS ARTICULATE PUSH ARM (standard) X=12.5 mm X=36.5 mm 18.5 X=60.5 mm X=84.5 mm Utilizable Length and weight Utilizable Length and weight with different fixing sizes NOT Utilizable Length and weight 0 ..250 mm 1000 1500 1) Fixing drawings available on request...
  • Page 9 SLIDE PULL ARM (standard) X=51.5 mm X=75.5 mm 18.5 0..200 9 mm X=99.5 mm 20.5 X=123.5 mm Utilizable Length and weight Utilizable Length and weight with different fixing sizes NOT Utilizable Length and weight 1000 1500 Fixing drawings available on request...
  • Page 10: Arm Connections

    8.0 ARM CONNECTION Warning: strictly comply with the steps described when fixing the arms. Only remove the spring preload locking screw when specified in the instructions. Removal of the spring preload locking screw causes the pulleys and gears in the actuator to move.
  • Page 11: Arm Removal

    9.0 ARM REMOVAL Warning: Strictly comply with the steps described when removing the arms. Only remove the screw that fixes the tapering pin and tighten the puller nut when specified in the instructions. Removal of the screw that fixes the tapered pin and use of the puller nut may cause the pulleys and gears in the actuator to move unless the closing spring has been previously locked.
  • Page 12: Extension Shaft

    10.0 EXTENSION SHAFT Where the conical shaft height should be not sufficente for the application, Is available an extension shaft (optional) to increase this height. For available heights refer to paragraph 7.0 First of all deconnect the arm from the conical connection by unscrew the two head screws.
  • Page 13 MAINTENANCE PROGRAM Maintenance program for swing door NEPTIS/LE: Each 6 month: ! Attention- Before work on the operator cut main power line. Check that all securing screws are well tightened. Clean and lubricate moving and sliding components. Lubricate closing spring if present.
  • Page 14 notes...
  • Page 15 NEPTIS/LE ELECTRONIC SECTION...
  • Page 16: Electrical Connections

    NEPTIS/LE 1) ELECTRICAL CONNECTIONS Fig.1 ! TERMINAL BOARD M1 230 V.a.c. power supply: phase wire to terminal F, neutral wire to terminal N + ground connection. The line is protected by the 5A fuse F1. ! TERMINAL BOARD M2 Terminals 1-3-4 = connection of the FUNCTION SELECTOR switch installed on the side of the device.
  • Page 17 The selector kit includes the “LOGIC TAST” interface board, which must be fitted into connector J8 (see fig. 2) so as to allow the selector to work with the "NEPTIS/LE” control unit. ! TERMINAL BOARDS M5-M6 = Dedicated to connection of photocell PRJ38 capsules; see sect. 12 for operation mode.
  • Page 18: Description Of Logic Part Lgn Of The Control Unit

    = connector for the photocell board. CONNECTOR J13 = connection between the MASTER and the SLAVE control unit for two-wing swing door (see sect. 13). Use the MASTER/SLAVE wiring for "NEPTIS/LE” mod.WR3MS. CONNECTOR J8 = connection for the LOGIC TAST interface module of selector.
  • Page 19: How To Reset The Spring Preload

    3) HOW TO RESET THE SPRING PRELOAD Only read this section if, during the installation phase, the arm is accidentally disconnected without the spring being returned to the standard position and relocked. If this happened, the spring would be relieved well beyond its preset level. The actuator is supplied with the reclosing spring preloaded with a standard value, whereby the red mark on the belt matches the red mark on the pulley (see figure alongside).
  • Page 20: How To Set The Device At Work (Initial Set-Up)

    4) HOW TO SET THE DEVICE AT WORK (INITIAL SET-UP) After having fixed the device to the door and loaded the spring (only for the SW version), move the wing as far as it will go by hand. Make sure that the movement is smooth, fluid, without friction and that it ends with the door fully against an end rabbet. Proceed with the initialization phase (initial set-up).
  • Page 21: Manual Function Selectors

    "NEPTIS/LE” unit. 5.2.1) ELECTRICAL CONNECTIONSI TERMINAL 1 = connect to input 9 (INTERNAL RADAR) of the PWN of the "NEPTIS/LE” control unit; TERMINAL 2 = connect to input 3 (COMMON CONTACT) of the PWN of the "NEPTIS/LE” control unit;...
  • Page 22: Functions Of Dip Switch S1

    FUNCTIONS OF DIP SWITCH S1 Select the functions by means of dip-switch S1 of the control unit or by means of the indicator light of the digital selector (consult sect. 9.2 for the settings of digital selector). Selector / Control unit DIP 1 ON = Push &...
  • Page 23: Functions Of Dip Switch S2 (Only Via Digital Selector)

    7) DIP SWITCH S2 FUNCTIONS (only via digital selector) Set up the functions by means of the indicator light of digital selector (see sect.9.2). DIP 1 ON = STEPPING function activated. One pulse opens and a seconde pulse closes The START and EMERGENCY inputs anre enabled. DIP 1 OFF = STEPPING function inhibited.
  • Page 24: Potentiometer Adjustments

    8) POTENTIOMETER ADJUSTMENTS FROM VIA CONTROL DIGITAL SELECTOR WORK PARAMETERS UNIT Note: If the program symbol is of a light colour, the led is on Opening speed Closing speed Safety sensor inhibiting distance in opening mode Pushing thrust limitation Pause time - max 20” - min. 0 Closing upkeep voltage Wind stop force intensity Push &...
  • Page 25: Digital Selector

    9) DIGITAL SELECTOR If the led is permanently on or flashing, it means that there is no communication between the selector and the control unit.. In this case, check the electrical connection Make sure that the LOGIC TAST module is installed. Input status indication..
  • Page 26: The Remote Control

    9.1) THE REMOTE CONTROL A radio receiver is built into digital selector. It can be used to control Label’s SPYCO series remote controls with both one and three channels. SPYCO remote controls transmit a rolling code (the code changes on each transmission according to a preset algorythm) and render the system immune to attempts to clone the code.
  • Page 27: Adjusting The Device With Remote Programming Via Selector

    9.2) Adjusting the device with remote programming via digital selector For the remote programming of DIP S1 and of potentiometers from TM1 to TM5 to become operative, DIP12 of S1 must be set to the ON position. The programming of all other parameters does not depend on DIP 12 of S1. Comply with the following instructions to access the programming mode: A) Move the selector’s locking key to the functions locked position B) Press the selector’s SET...
  • Page 28: Courtesy Mode For The Disabled

    ! Move dipswitch 8 of S1 to the ON position to enable the courtesy function for disabled persons. Two inputs of the "NEPTIS/LE” unit, i.e. START and EMERGENCY, are dedicated to the use of special opening buttons able to be used by disabled persons.
  • Page 29 TABLE 12.1 DIP SWITCH S2 DIP SWITCH "NEPTIS/LE” NUMBER OF PHOTOCELLS INSTALLED AND THEIR USE CONTROL UNIT PHOTOCELL (to be set with BOARD digital selector) DIP8 DIP9 DIP1 DIP2 1 CLOSING SAFETY PAIR (FT3/FR3) 1 PAIR AS OPENING CONTROL (FT1/FR1) PAIRS AS OPENING CONTROL (FT1/FR1 &...
  • Page 30: Swing Door With Two Wings

    13) SWING DOOR WITH TWO WINGS A door with two wings can be controlled by using two "NEPTIS/LE” actuators. Carefully consult the drawings in the “MECHANICAL SECTION” at the beginning of this manual in order to establish the fixing dimensions, opening direction of the wing and the maximum weight allowed by the wing length. The system comprises a main control unit, which must be configured as the MASTER and whose task is to handle the general operation of the door, and a second control unit configured as the SLAVE, which receives orders and information from the MASTER.
  • Page 31: 1) Actuator With Master Control Unit

    Strictly comply with the instructions given below in order to install the device in the correct way: A) Fix the two "NEPTIS/LE” actuators in compliance with the dimensions and wing opening direction shown in the drawings in the mechanical section of this manual.
  • Page 32: Functions And Adjustments

    13.3) FUNCTIONS AND ADJUSTMENTS After installing the device and completing the initial set-up, proceed with the adjustments by selecting the parameters required to synchronize the system. 13.3.1) HOW TO ADJUST THE MASTER ACTUATOR A) Connect digital selector to the MASTER control unit without forgetting to fit the LOGIC TAST module into connector J8 of the control unit.
  • Page 33: Pedestrian Opening

    14) PEDESTRIAN OPENING The pedestrian opening function can only be used for a swing door with two wings. It is therefore essential for the actuators to be set up for operation as a DOUBLE-WING DOOR (see sect.13). To enable the PEDESTRIAN OPENING function, set dipswitch 4 of S2 ON and select the condition which activates the function by means of dipswitch 3 of S2.
  • Page 34: Meanings Of The Buzzer Signals (Beeps)

    5) END OF TRAVEL DISTANCE ON OPENING 6) PUSHING POWER AT END OF OPENING MANOEUVRE 7) PUSHING POWER AT END OF CLOSING MANOEUVRE ("NEPTIS/LE” version only) 8) NOT USED 9) PUSHING TIME AT END OF CLOSING MANOEUVRE ("NEPTIS/LE” version only)
  • Page 35: Advanced Functions - Technical Menu

    18) ADVANCED FUNCTIONS - TECHNICAL MENU The adjustments in the technical menu allow you to change the various door operating parameters.This is of use when the default settings are not the optimal ones. digital selector must be available for access to the TECHNICAL MENU. enter the program from digital selector, turn the key to the horizontal function locking position, press the two keys , and keep them depressed, then turn the key back to the vertical work position.
  • Page 36 Press the SET key to access the point 7 adjustment option. 7) PUSHING POWER AT END OF CLOSING MANOEUVRE ("NEPTIS/LE” version only) This is the pushing power in the last section of the closing phase. It is useful for preventing friction in the lock from being detected as an obstruction and preventing the manoeuvre from being completed.
  • Page 37 12)WIND STOP FORCE INTENSITY ON OPENING Helps to keep the device in the “door open” status, preventing the wind or other causes from closing accidentally. Increase the value to obtain a stronger force. Press the SET key to access the point 13 adjustment option. 13) WING DELAY ON OPENING This parameter can only be adjusted after the “DOUBLE-WING DOOR”...
  • Page 38 notes...
  • Page 40 Made in Italy AZIENDA CERTIFICATA SISTEMA QUALITA' UNI EN ISO 9001:2000 S.p.A. Via Ilariuzzi, 17/A - S. Pancrazio P .se - 43100 PARMA - ITALIA - Tel. (+39) 05 21/ 67 52 - Fax (+39) 05 21/ 67 52 22 e-mail: infocom@labelspa.it - http://www.labelspa.it...

Table of Contents