The Java Client

For mouse synchronization problems, refer to the discussion on page 17. For connection and
operation problems, see the table below:
Symptom
Java Client won't
connect to the
B014-000
Java Client
performance
deteriorates.

Administrator Login Failure

If you are unable to perform an Administrator login (because the Username and Password
information has become corrupted, or you have forgotten it), you can clear the login informa-
tion with the following procedure:
1. Power off the B014-000 and remove its housing.
2. Short the jumper on the mainboard labeled J6.
3. Power on the switch.
4. When the front panel LEDs flash, power off the switch.
5. Remove the jumper cap from J6.
6. Close the housing and start the B014-000 back up.
After you start back up, you can use the default Username and Password (see p. 8) to log in.
Action
1. Make sure to include the correct name of the web page when you
specify the B014-000's IP address.
2. Close the Java Client, reopen it, and try again.
Exit the program and start again.