Lincoln Electric POWER FEED 25M NNS Operator's Manual page 45

For use with machines having code numbers 12244
Table of Contents

Advertisement

POWER FEED™ 25M NNS
If the passcode does not equal zero (0000), enter the
passcode now. If the passcode has been forgotten, a
p.c. computer application is required to change the
passcode.
Memory Value
High Limit
200
HI = 200 LOW = 180
WELD WFS
WELD MODE
ARC CONTROL
Parameter Name
If the passcode has been set to zero (0000), SETUP will
illuminate on the user interface and the display will show
the following:
Four items show on the user interface.
• Memory Value
• High Limit
• Low Limit
• Parameter Name
One of these items will flash to indicate which item will
change when the user interface encoder is rotated.
Press the right button on the user interface to select the
item to change.
200
HI = 200 LOW = 180
WELD WFS
WELD MODE
ARC CONTROL
Rotate to
Change
Value.
The Limits Setup menu shows a list of all parameters
available for the weld mode stored in the memory cho-
sen. For example, if limits are being set for a stick
(SMAW) mode, parameters such as Run-in WFS and
Postflow will not appear.
To lock a parameter to a specific value that cannot
be changed, set the high and low limits to the
same value.
Low Limit
SETUP
START OPTIONS
END OPTIONS
SET
SETUP
START OPTIONS
END OPTIONS
SET
Press to
select item
to change.
The memory value must always be less than or equal
to the high limit, and greater than or equal to the low
limit.
After setting limits, press the memory button with the
flashing LED. The display will ask to save or discard
the limit changes just made. Press the left user inter-
face for button (YES) to save and enable the limits
and exit. Press the right button (NO) to exit and leave
limits unchanged.
Enabling/Disabling Limits
Enable/Disable
Limits: Press
10 seconds
A
GUN B
1
5
Limits for each memory may be enabled or disabled
by pressing and hold the appropriate memory button
for 10 seconds. Release the memory button when the
display shows the following:
MEMORY 2
ENABLE/DISABLE
WELD MODE
ARC CONTROL
If the passcode does not equal zero, enter the passcode
now. If the passcode is zero (0000), SETUP will light
and the displays the following:
ENABLE
Yes
WELD MODE
ARC CONTROL
Press the left button (YES) to enable limits or the right
button (NO) to disable limits. Disabling limits does not
change any limits values that may have been previ-
ously set.
B 30
OPERATION
M
M
2
3
4
6
7
8
LIMITS
START OPTIONS
END OPTIONS
LIMITS?
SETUP
No
START OPTIONS
END OPTIONS
SET