POWER FEED™ 25M NNS
Parameter
P.22
Arc Start/Loss Error Time
This option can be used to optionally shut off output if an arc is not established, or is lost for a
specified amount of time. Error 269 will be displayed if the machine times out. If the value is set
to OFF, machine output will not be turned off if an arc is not established nor will output be
turned off if an arc is lost. The trigger can be used to hot feed the wire (default). If a value is
set, the machine output will shut off if an arc is not established within the specified amount of
time after the trigger is pulled or if the trigger remains pulled after an arc is lost. This is disabled
while welding in Stick, TIG or Gouge. To prevent nuisance errors, set Arc Start/Loss Error Time
to an appropriate value after considering all welding parameters (run-in wire feed speed, weld
wire feed speed, electrical stick out, etc). To prevent subsequent changes to Arc Start/Loss
Error Time, the setup menu should be locked out by setting Preference Lock = Yes using the
Power Wave Manager software.
P.27
Language Select
Selects which language will be displayed on the User Interface.
English (Default)
Deutsch
Polski
P.28
Display Workpoint as Amps Option
This option determines how workpoint is displayed.
False = The workpoint is displayed in the format defined in the weld set (default).
True = All workpoint values are displayed as an amperage.
Note: This option may not be available on all machines. The power source must support this
functionality, or this option will not appear in the menu.
P.80
Sense From Studs
Use this option for diagnostic purposes only. When power is cycled, this option is automatically
reset to False.
False = Voltage sensing is automatically determined by the selected weld mode and other
machine settings (default).
True = Voltage sensing is forced to "studs".
P.81
Electrode Polarity
Used in place of DIP switches for configuration of the electrode sense lead. This option allows selec-
tion of the electrode voltage sense polarity. Most GMAW welding procedures use Electrode Positive
welding. Most GTAW and some inner shield procedures use Electrode Negative welding.
Positive Electrode Welding (default).
Negative Electrode Welding.
This option will only appear in the menu if the feedhead board does not have a dip switch to set the
polarity, and the power source does not support auto-hardware sense lead configuration. If this
option does not apper in the menu, voltage sense polarity can be selected using the dip switches.
USER DEFINED PARAMETERS
Definition
Italiano
Francais
Espanol
B 24
OPERATION