Lincoln Electric POWER FEED 25M NNS Operator's Manual page 40

For use with machines having code numbers 12244
Table of Contents

Advertisement

POWER FEED™ 25M NNS
Parameter
P.82
Voltage Sense Display
Allows viewing of Voltage Sense Lead Selection to aid in troubleshooting. The configuration is
displayed as a text string on the lower display whenever the output is enabled. This parameter
is not saved on a power cycle, but will be reset to False.
P.99
Show Test Modes
Most power sources contain weld modes used for calibration and test purposes. By default, the
machine does not include test weld modes in the list of weld modes that are available to the
operator. To manually select a test weld mode, set this option to "Yes". When the power source
is turned off and back on again, the test modes will no longer appear in the mode list. Test weld
modes typically require the machine output to be connected to a grid load and cannot be used
for welding.
P.100
View Diagnostics
Diagnostics are only used for servicing or troubleshooting the Power Wave system. Select
"Yes" to access the diagnostic options in the menu. Additional parameters will now appear in
the setup menu (P.101, P.102, etc).
P.101
View Event Logs
Used for viewing all the system event logs. Press the Right Button to enter the option. Rotate
Control Knob to select the desired event log to read. Press the Right Button again to enter the
selected log. Rotating the Control Knob will scroll through the event log, displaying the log index
number, event code and some other data. Press the Left Button to back out to select another
log. Press the Left Button again to exit this option.
P.102
View Fatal Logs
Used for viewing all the system fatal logs. Press the Right Button to enter the option. Rotate
Control Knob to select the desired fatal log to read. Press the Right Button again to enter that
log. Rotating the Control Knob will scroll through the log, displaying the log index number and
fatal code. Press the Left Button to back out to select another log. Press the Left Button again
to exit this option.
P.103
View Software Version Information
Used for viewing the software versions for each board in the system. Press the Right Button to
enter the option. Rotate Control Knob to select the desired board to read. Press the Right
Button again to read the firmware version. Press the Left Button to back out to select another
board. Rotate the Control Knob to select another board, or press the Left Button to exit this
option.
P.104
View Hardware Version Information
Used for viewing the hardware version for each board in the system. Press the Right Button to
enter the option. Rotate Control Knob to select the desired board to read. Press the Right
Button again to read the hardware version. Press the Left Button to back out to select another
board. Press the Left Button again to exit this option.
P.105
View Welding Software Information
Used for viewing the Weld Set in the Power Source. Press the Right Button to read the Weld
Set version. Press the Left Button to back out and exit this option.
USER DEFINED PARAMETERS