POWER FEED™ 25M NNS
Parameter
P.106
View Ethernet IP Address
Used for viewing the IP address of Ethernet compatible equipment. Press the Right Button to
read the IP Address. Press the Left Button to back out and exit this option. The IP address can-
not be changed using this option.
P.107
View Power Source Protocol
Used for viewing the type of power source the feeder is connected to. Press the Right Button to
identify the power source as either LincNet or ArcLink. Press the Left Button to back out and
exit this option.
P.350
User Interface Group Selection
Used to differentiate multiple PF25M feeders connected to the same power source. Each inde-
pendent feeder must have a unique selection in order to resolve error 18 problems.
P.500
View Lockout Parameters
Originally used to prevent inadvertent changes of secure setup parameters, P.500 was previ-
ously used as a gateway to these parameters. Presently, this option does not exist in any setup
menu.
P.501
Encoder Lockout
Locks one or both of the upper knobs (encoders), preventing the operator from changing wire
feed speed, amps, volts or trim. The function of each upper knob depends on the selected weld
mode. When a constant current weld mode is selected (e.g. Stick, TIG, Gouge), the upper right
knob will always function as an on/off switch. This parameter can only be accessed using
Power Wave Manager software.
P.502
Memory Change Lockout
Determines if the memories can be overwritten with new contents.
• No = Memories can be saved and limits can be configured (default).
• Yes = Memories cannot be changed - saving is prohibited and limits cannot be re-configured.
This parameter can only be accessed using Power Wave Manager.
P.503
Memory Button Disable
Disables the specified memory button(s). When a memory is disabled, welding procedures can-
not be restored from or saved to that memory. If an attempt is made to save or restore a dis-
abled memory, a message will be displayed on the lower display indicating the memory number
is disabled. In multi-head systems, this parameter disables the same memory buttons on both
feed heads. This parameter can only be accessed using Power Wave Manager software.