  • Page 1 StarEye Maxi RGBW With RDM Order code: 10704...
  • Page 2: Table Of Contents

    9 WARRANTY ................14 ..............14 PPLICATION OF WARRANTY ................16 PROCEDURE 10 LIST OF USED ABBREVIATIONS ............17 StarEye Maxi RGBW LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.2/17 T: +32 3 293 35 50 – www.lux-lumen.com...
  • Page 3: Picture

    (included) with snoot (optional) 1.2 Range of lenses 9° 11° 23° 32° Real spot Spot Medium Wide StarEye Maxi RGBW LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.3/17 T: +32 3 293 35 50 – www.lux-lumen.com...
  • Page 4: Dimensions

    The dimensions of the main housing, a cylindrical lathed part, are Ø63mm with 165 mm length. The maximum height with bracket: 100 mm (accessories exclusive) StarEye Maxi RGBW LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.4/17 T: +32 3 293 35 50 – www.lux-lumen.com...
  • Page 5: Safety Information

    Safety information Before installing, powering up, or servicing the StarEye Maxi RGBW led-unit, it is highly recommended that you read this manual and ensure yourself that you completely understand its content. Observe the safety precautions in this manual. Install and operate the led-unit only as described in this manual, and in conformity with local regulations.
  • Page 6: Protection From Electric Shock

    It might be necessary to allow the led-unit to cool down for 5 minutes, before servicing. Do not modify the led-fixture, in a way, not described in this manual. StarEye Maxi RGBW LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.6/17 T: +32 3 293 35 50 – www.lux-lumen.com...
  • Page 7: Protection From Injury

    StarEye Maxi RGBW LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.7/17 T: +32 3 293 35 50 – www.lux-lumen.com...
  • Page 8: Physical Installation

    Physical installation Thank you for selecting this StarEye Maxi RGBW led-unit as best solution in your setup. Warning! Read the safety precautions in this manual before integrating this led-unit into your installation. Installation must be carried out by qualified professionals only.
  • Page 9: External Connections

    In case of inversed polarity, the warranty is void. Power supply: Rated voltage The rated input voltage range of the StarEye Maxi RGBW led-fixture is 24 VDC. Due to the use of a step down-convertor, integrated in the housing, a highly efficient system is created.
  • Page 10: Emc And Safety Requirements

    EMC and safety requirements The StarEye Maxi RGBW led-unit is fully compliant to the LVD and EMC directive of the European council, if used in a properly designed setup. The StarEye Maxi RGBW led-unit is only intended to be used in lighting...
  • Page 11: Installation Setup

    Installation setup 7.1 Specification The StarEye Maxi RGBW led-unit is a small and efficient solution for detail lighting. The ingress protection of the StarEye Maxi RGBW led-unit is IP67, and as such, the led-unit can be used in outdoor as well as indoor applications.
  • Page 12: Service And Maintenance

    Never use solvents to clean the outer housing of the unit. Never use water, or wet cloth. StarEye Maxi RGBW LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.12/17 T: +32 3 293 35 50 – www.lux-lumen.com...
  • Page 13: Changing Lenses

    Screw the front cover onto the housing clockwise. Do not displace the rubber band to prevent fluid ingress StarEye Maxi RGBW LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.13/17 T: +32 3 293 35 50 – www.lux-lumen.com...
  • Page 14: Warranty

    Lux Lumen Kernenergiestraat 53 A 2610 Wilrijk Belgium Any cost of secure transportation of the product to and from Lux Lumen service department, will be borne by the customer. Limitations Lux Lumen will not warrant the following: • Periodic check-ups, maintenance and repair or replacement of parts due to normal wear and tear.
  • Page 15 IP and IK degree, mentioned in the product specifications in this manual. Repairs, modifications or cleaning carried out by a non Lux Lumen service centre. Use of spare parts, software or consumables, which are not compatible with the product.
  • Page 16: Rma Procedure

    Customer sends material (include a copy of the RMA document with the material) Step 4: Lux Lumen evaluates and informs the client if repair is under warranty, or -if not - makes an offer for repair to the client. StarEye Maxi RGBW LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.16/17...
  • Page 17: List Of Used Abbreviations

    • FWHM: Full Width Half Measurement • RMA: Return Material Authorization • LVD: Low Voltage Directive • EMC: ElectroMagnetic Compatibility StarEye Maxi RGBW LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM p.17/17 T: +32 3 293 35 50 – www.lux-lumen.com...