Dimensions The StarPole consists of various elements. In the setup with a Base plate, a StarPole Head and a StarPole pole the total dimension is: L 340 x W 400 x H 3675mm/2775mm L (cm) W (cm) H (cm) HEAD...
5p connector at the bottom. The 6 StarEye Maxi spots are controlled per 2 by a LED driver 6ch. 1 StarPole uses 3 outputs of a 6ch LED driver. It is possible to connect 2 StarPoles to each LED driver.
Specification The StarPole luminaire is an elegant and efficient solution for indoor event lighting. • Power consumption max. 60 watt (6x10W) • Power voltage: 24 volt DC • Current: max 3A (full rated output) • Weight: 15,4kg • Possible lenses: Spot: 22°...
Page 7
• Single blinking green LED: Link from transmitter, radio • Double blinking green LED: Active radio, no DMX StarPole p.7/22 LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM T: +32 3 293 35 50 – F: +32 3 293 35 44 www.lux-lumen.com...
All parts are delivered in dedicated transportation cases. • Case for 16 x StarPole Base plate: • Case for StarPole Cabling: • Case for 12 StarPole poles (image: 5 cases, piled up): StarPole p.8/22 LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM T: +32 3 293 35 50 –...
Installation Please additionally consult the document with the StarPole Assembly overview. Provide the StarEyes with the correct optics Step 1: Screw the front cover counterclockwise to remove it from the led-unit. Step 2: Take out the old lens. Don’t touch the LED itself to avoid damage to the StarEye! Step 3: Insert the new lens into the led-unit.
Place head on pole Place the top part on the pole and secure the joint with bolts. StarPole p.13/22 LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM T: +32 3 293 35 50 – F: +32 3 293 35 44 www.lux-lumen.com...
Cable The cable used in the StarPole is 4x#0,5mm with a XLR 5p connector on top and a wago 5 connector at the bottom. It is possible to extend the cable with a cable 4x#1,5mm of maximum 25m until the 6ch LED Driver.
EMC and safety requirements The StarPole is fully compliant to the LVD and EMC directive of the European council, if used in a properly designed setup. EMC requirements of the power supply The StarPole luminaire is only intended to be used in lighting applications, and as such, the complete assembly of led-unit and power supply needs to be fully compliant with the harmonized standards.
Safety information Before installing, powering up, or servicing the StarPole luminaire, it is highly recommended that you read this manual and ensure yourself that you completely understand its content. Observe the safety precautions in this manual. Install and operate the led-unit only as described in this manual, and in conformity with local regulations.
Do not modify the LED fixture, in a way, not described in this manual. StarPole p.19/22 LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM T: +32 3 293 35 50 – F: +32 3 293 35 44 www.lux-lumen.com...
Never use solvents to clean the outer housing of the unit. Never use water, or wet cloth. StarPole p.21/22 LUX LUMEN - Kernenergiestraat 53A - 2610 WILRIJK - BELGIUM T: +32 3 293 35 50 – F: +32 3 293 35 44 www.lux-lumen.com...