Page 1
Z-3272 Hanheld 2D Image Reader Service Guide Revision History Changes to the original manual are listed below: Version Date Description of Version January 17, 2017 Initial release...
This scanner is in conformity with CE standards. Please note that an approved, CE-marked power supply unit should be used in order to maintain CE conformance. This manual is in A4 format. Please check your printer setting before printing it out. Z-3272 Service Guide 2 / 11...
Table of Contents Preface..................................2 Important Notice ..................................2 Radio Notice...................................2 Radio and Television Interference............................2 For CE-Countries ...................................2 Table of Contents................................3 Scanner Parts ..................................4 Take Apart ..................................5 Before You Start ..............................6 Important Instructions ..............................6 Tools to Prepare ..................................6 Z-3272 Service Guide 3 / 11...
Follow all instructions. • Heed all warnings. Tools to Prepare • Philips screwdriver. Please follow these steps to take apart the scanner. Remove the screws (521-00E000-8R0). Separate the top case from the handle base. Z-3272 Service Guide 6 / 11...
Page 7
ERVICE UIDE Remove the dust cover from handle base. Remove the screws (521-002000-6R0*4) and the washers. Remove Mylar tape then remove the 16Pin FFC cable. Z-3272 Service Guide 7 / 11...
Page 8
ERVICE UIDE Remove the main board and handle base. Remove the main board and the buzzer. Remove the screws (521-00E000-8R0*2). Z-3272 Service Guide 8 / 11...
Page 9
ERVICE UIDE Remove the trigger and the I/O board assembly 10. Remove the screw (521-00E000-8R0). 11. Separate the base cover and the handle base Z-3272 Service Guide 9 / 11...
Page 10
ERVICE UIDE 12. Remove the Mylar tape. 13. Remove the 16Pin FFC cable. 14. Remove the screws (521-013000-5R0*3). Z-3272 Service Guide 10 / 11...
Page 11
ERVICE UIDE 15. Separate the trigger support and the rubber. Z-3272 Service Guide 11 / 11...