9.6.5.

Battery replacement

In the online-mode the AccessPoint receives the battery charge level of every connected DoorLock-device.

On a low charge level an e-mail is sent to all users that have the notification option activated. The device can
then still be used, but the batteries should be replaced soon. About 1000 bookings can then be made.
The DoorLock-device (online- and offline-mode) optically and acoustically signalizes that a replacement of the
batteries is necessary during the last 1000 bookings.
The signalization has 3 stages:
Nr
Battery warning phase 1:

1
The online-cylinder / door lever can still be used,
batteries should be replaced soon.
Battery warning phase 2:
The online-cylinder / door lever can still be used, the
2
engaging is delayed. Batteries must be replaced.

Battery warning phase 3:

Opening of the door is no longer possible.
The batteries must be replaced.

3
The knob unlocks the locking pins for the battery
change. The cover of the knob can be taken off with
the battery replacement tool.
When reaching a low battery charging level the batteries should be replaced as soon as possible.
For the replacement of the batteries the cover of the knob has to be removed. If the batteries are fully
discharged, the opening of a knob is only possible using a low-power-adapter (see also the chapter „emergency
opening").
To remove the cover, hold the battery changing card in front of the knob. The knob then releases the locking
pins. Now the cover can be taken off by pressing the two pins with the battery replacement tool and pulling the
cover back.
The batteries can then be taken out. After the exchange the cover has to be put over the knob again. The
locking pins can be pushed down easily with thumb and forefinger.
To complete the process, the battery changing card has to be held in front of the knob once again.
To replace the batteries at a door lever, the Allen screw has to be opened on the electronic side of the lever. The
front part of the lever can then be pulled off. The battery is located inside the lever and can now be simply taken
out.
ATTENTION!
The Allen screw has to be screwed clockwise into the lever to open it.
For the battery replacement at a cabinet lock the battery compartment has to be pulled out after inserting the
battery changing tool. The battery can then be exchanged and then inserted again together with the
compartment.
Page
90
Stage
(07-2018, subject to change)
Note / Signalization
5x short sound, LEDs flash red simultaneously
5x short sound, LEDs flash red simultaneously
5s delay of the engagement, LEDs flash green
5x short sound, LEDs flash red simultaneously
no engagement / opening of the door