Logbook data - Remove user related data after
Defines for how long user accesses / bookings will be stored in the AccessPoints database. Several periods are
available here. „Store all" will provide space for up to 200.000 bookings.
Security - PIN Length
Defines the number of digits when using IP wall readers with PIN.
Security - Mifare Desfire
Kentix DoorLock can request application data from the users RFID media. By default this feature is inactive, so
that only the cards ID is requested and compared.
NOTE!
This option will only work together with RFID tokens prepared by Kentix. The application data already has
to be present on the card and cannot be written during operation.

9.6.2.11. Access - DoorLocks - Switching alarm zones

The following requirements must be fulfilled for switching an alarm zone on the AlarmManager:
1. The same communication key must be entered in AccessPoint and AlarmManager.
2. In the AccessPoint (section „Configuration" -> „Communication") the AlarmManager must be entered with IP-
address and a valid user.
3. An alarm zone must be selected for the Online knob / door lever or wall reader in the section „Access" ->
„DoorLocks".
4. The option „Time control" for the permanently engaged mode must not be active.
For booking and simultaneous switching please proceed as follows:
DISARMED
- One-off booking disarmes the assigned alarm zone
ARMED
- Booking twice at a maximum of 15 seconds will activate the alarm zone. For the second
booking, the RFID card must also be held in front of the knob until the arming is signaled
visually and acoustically at the knob.

Page
83
(07-2018, subject to change)