Step 3: Mark boreholes
Place the drilling template on the square pin, align horizontally and center punch the hole markings.
Step 4: Drill holes
Remove the square pin again. Drill holes with a diameter of 8 - 8,5 mm at the marked positions.
ATTENTION! Do not drill into or through the lock casing!
Step 5: Install electric door lever
Insert the square pin of the electric door lever once again into the square nut of the lock.
Insert the handle holder of the mechanical door lever from the other side and screw it along with the electronic
door lever through the door panel using the supplied mounting screws.
ATTENTION!
The included mounting screws are designed for doors with a larger door thickness. Before
inserting the screws it is important to check whether these have to be shortened before. Otherwise
the door rosettes might be damaged.
Page
59
(07-2018, subject to change)