1Ru Fan Cable - Barco Event Master E2 Series User Manual

Hide thumbs Also See for Event Master E2 Series:
Table of Contents

Advertisement

Image 14-87
8.
Remove the 3RU cable by gently pushing it out.
How to install the 3RU Fan Cable
To install the 3RU Fan Cable follow the same procedure in the reverse order.

14.31 1RU Fan Cable

Flow chart
Image 14-88
The 1RU cable assembly provides power to the 1RU fans from the System-Power board.
One side of the cable is attached to a metal bracket that is accessible after the 3RU and the 1RU
fan trays are removed. The other side of the cable assembly connects to the System-Power board
and is accessible when the bottom panel is removed.
Concerned parts
R767269K Cable Kit Set
Necessary tools
1 x Phillips Screwdriver #2
Hex Screwdriver
E2 Maintenance
R5905948 /12
Event Master Devices
435