3.0 OPERATION

Contact the factory, the factory representative or a local service company to perform
maintenance and repairs should the appliance malfunction.
CAUTION: If you smell gas during the lighting procedure, immediately shut off the
gas supply until the leak has been corrected.
WARNING: In the event of main burner ignition failure, a 5 minute purge period
must be observed prior to re-establishing ignition source.
WARNING: In the event you smell gas, shut down equipment at the main shut off
valve and contact the local gas company or gas supplier for service.
GAS CONTROL INSTRUCTIONS
The units do not require "lighting" the pilot with a match.
A. Lighting
NOTE: Unit is shipped with gas combination valve turned "on".
1. Open manual gas shut off valve.
2. Set thermostat to OFF, and kettle in fully upright position, turn power switch ON.
3. Set thermostat to maximum, initiating a 30 second pre-purge. Red "COOKING" pilot will
come on, and after 30 seconds, the green "IGNITION" pilot will come on, lighting the main
burners.