Operation; Gas Start-Up And Shutdown - Blodgett KLS-G SERIES Installation Operation & Maintenance

Gas stationary steam jacketed kettle

Advertisement

WARNING
In the event of main burner ignition failure, a
5 minute purge period must be observed prior
to re-establishing ignition source.
WARNING
In the event you smell gas, shut down equip-
ment at the main shut off valve and contact
the local gas company or gas supplier for
service.
CAUTION
If you smell gas during the lighting procedure,
immediately shut off the gas supply until the
leak has been corrected.
GAS CONTROL INSTRUCTIONS
Appliance does not require "Lighting" the pilot with a
flame.
START-UP
1. Turn thermostat to "OFF" position and power switch
to "OFF" position.
2. Open control panel access door located on right side
at bottom.
3. Turn dial on combination control to "ON" position by
rotating control knob counterclockwise.
NOTE: Any gas service valves exterior to the unit
should be open.
4. Turn "POWER" switch to "ON" position.
5. Set "COOK TEMP" to desired setting. The red
"COOKING" pilot will be on until desired setting has
been reached.
6. At this time the spark igniter will begin sparking at the
pilot until the pilot is ignited, or for ninety seconds (an
audible clicking sound will be evident).
7. When the pilot is ignited the spark igniter will auto-
matically stop and within 15 seconds main burner gas
will come on. If ignition does not occur, after a total of
ninety seconds, the unit will lockout, shutting off all
gas although the spark igniter will continue to spark.
New installations (where there may be a considerable
amount of air in the gas line) may require the unit
to be turned off and immediately back on numerous
times after each lockout period until the air is purged
from the gas line.

Gas Start-up and Shutdown

SHUTDOWN
Standby
1. Place power on switch and thermostat to "OFF" posi-
tion.
Complete
1. Place power on switch and thermostat to "OFF" posi-
tion.
2. Turn dial on combination control from "ON" position to
"OFF" position.
3. Turn any main gas service valves supplying gas to
"OFF" position.
Relighting
1. Turn power switch to "ON" position.
It should be noted that the pilot and electronic ignition do
not cycle with the thermostat. A standing pilot is auto-
matically established and monitored each time the power
switch is turned ON. If the pilot is ever extinguished by a
momentary external interruption, the spark igniter will au-
tomatically relight it without disturbing the cooking cycle,
unless lockout occurs.
SPARK IGNITER FAILURE
In the event the spark igniter module fails the unit may
still be operated by carefully following these instructions.
1. Turn thermostat to OFF position; completely counter-
clockwise.
2. Turn power switch to OFF position.
3. WAIT A MINIMUM OF 5 MINUTES BEFORE PRO-
CEEDING.
4. Turn dial on combination control to ON position (if not
already on).
5. Turn power switch to ON position.
6. Wait two minutes and ten seconds and then immedi-
ately light pilot with long match or taper.
7. After 10 - 15 seconds gas valve will allow main burner
gas to flow when thermostat is turned on.
8. The pilot will now stay ignited as long as the power
switch remains ON. If power switch is turned OFF,
repeat the above instructions. It is intended that the
unit be operated in this manner only in emergency
situations and only while it is attended (do not leave
pilot lit overnight; shut off power switch). A qualified
serviceman must be called promptly.