Page 1
Keysight U1610/20A Handheld Digital Oscilloscope Quick Start Guide...
Page 2
Category II overvoltage CAT II protection Category III overvoltage CAT III protection For further safety information details, refer to the Keysight U1610/20A Handheld Digital Oscilloscope User’s Guide. Keysight U1610/20A Quick Start Guide...
Compensate the Scope Probe ... . 15 Access the Quick Help ....16 Keysight U1610/20A Quick Start Guide...
Page 4
THIS PAGE HAS BEEN INTENTIONALLY LEFT BLANK. Keysight U1610/20A Quick Start Guide...
Page 5
✔ 1 x Neck strap ✔ Printed Quick Start Guide ✔ Certificate of Calibration If anything is missing or damaged, contact the nearest Keysight Sales Office. All related documents and software are available for NOTE download at www.keysight.com/find/hhTechLib. Keysight U1610/20A Quick Start Guide...
AC/DC adapter provided. If the battery is fully discharged after subsequent use, charge the battery with the handheld scope turned on. The power key will turn constant yellow when the battery is fully charged. Keysight U1610/20A Quick Start Guide...
Hook up all cables and accessories before applying NOTE power. You can connect/disconnect probes while the handheld scope is turned on. Press and hold for approximately 3 seconds. When the handheld scope display appears, the handheld scope is ready for use. Keysight U1610/20A Quick Start Guide...
To set the system, and help vertical scaling functions. (volt/div) and vertical offset. Power key Meter terminals Horizontal controls To control the sweep speed (sec/div) and horizontal position of the waveform. Use to zoom into the waveform. Keysight U1610/20A Quick Start Guide...
Page 10
9 Displays the acquisition, start date and time, and duration status. 10 Displays the measurement. 11 Displays the virtual measurement scale. 12 Displays the average, maximum, and minimum values. 13 Indicates the auto or manual ranging mode. 14 Displays the logging graph. Keysight U1610/20A Quick Start Guide...
Before resetting to factory default settings, you may NOTE want to save the current handheld scope configuration for later use by pressing > For details on using the oscilloscope functions, see NOTE the User’s Guide. Keysight U1610/20A Quick Start Guide...
The data logger acts as a recorder to log and plot input signal trends for both scope and meter measurements. To access the logger mode, press For details on using the logger functions, see the NOTE User’s Guide. Connect Probes to Oscilloscope Terminals Keysight U1610/20A Quick Start Guide...
✔ °F ✔ ✔ ✔ [a] Frequency measurement works in the autorange mode, and the range that you select applies for V AC. For details on using the meter functions, see the NOTE User’s Guide. Keysight U1610/20A Quick Start Guide...
BNC adapter Use a nonmetallic tool to adjust the trimmer capacitor on the probe for the flattest pulse possible. trimmer capaciitor For details on adjusting the probe compensation for NOTE a channel, see the User’s Guide. Keysight U1610/20A Quick Start Guide...
To view Help in another language, press > NOTE > and use the keys. Press again to exit the selection menu. To access information on using Help, press and hold NOTE for approximately 3 seconds. Keysight U1610/20A Quick Start Guide...