7 Operating the Application
7.3 Live demo
No.
4.
When the scale is reached, and the
conditions standstill and weight recording
larger than zero have been fulfilled:
the scale is tared,
the setpoint specification (8) is
calculated:
m
= m
setpoint
setpoint
cell)
the sliders for filling (9) are opened.
5.
Fill the container with the selected wall
anchor type.
6.
Continue to fill the container with the
selected dowel type.
7.
The weight reached is compared with the
setpoint specifications as soon as the scale
comes to a standstill.
The quality is positive (true), when
m
<= m
setpoint
actual
Outside of these limits, the quality is
assessed as negative (false). The
determined values are saved as new entry
in the DataLog file.
8.
Finally the assessed packet is removed.
Remove the packet from the scale and
place a new empty container on the empty
scale for the next filling process.
During transport and filling, the process can be stopped via
with
The filling process is cancelled via
position on the conveyor belt simulation.
Weighing, Controlling and Logging (Set 6)
Entry ID: 82454336,
V2.0,
Action
(recipe) + m
(load
resolution
<= m
+ m
setpoint
torance
.
10/2017
Comment
The filling process is indicated by
the flashing blue arrow.
The setpoint weight deviation is
displayed on the packet.
As of 90% of the setpoint weight
(>-10% of the weight deviation)
the 2nd slider is closed and
reduces the filling speed.
The slow filling speed is indicated
by the flashing white arrow.
From 100% of the setpoint weight
(>=0% of the weight deviation)
the 1st slider is also closed and
filling is finished.
and the packet is reset to the initial
and continued