5.4.1 FILTERING OFF MODE
To enable/disable filtering off mode, the button should be pressed for 4 seconds.
OFF: filtering turned off. In this mode, the events schedule is
AUX
F
ignored, the filtering output turned off, resulting in reduced
off
4 segundos
power consumption.
Note: When adjusting the filtering mode, the controller changes into the new mode 5
seconds after your selection. This is also the time required for the parameter to be stored
in its memory.
5.5 TIME AND DAY SETTINGS
In order to access the Time and Day menu, just give a short touch on the
the or keys it is possible to navigate among the parameters. In order to edit them press
the SET key and through the or keys update its value. By pressing once again the
SET key, you return to the parameter menu.
Clock - Time settings.
Day - Day of the week settings.
Adjustable from 1 (Sunday) to 7 (Saturday).
NOTICE:
The controller is equipped with a lithium rechargeable battery in order to keep its
date and time in the case of an energy shortage. A fully charged battery can provide
enough energy to keep the time and date running for some weeks. If the controller
remains turned off for a prolonged period of time, it will display the message
[ECLO], in this case the controller's date and time has been lost due to low battery
and the user must adjust it again. To completely recharge a dischaged battery, keep
the controller turned on for at least 10 hours.
Obs.: In the parameter menu, to leave and return to normal operation (preferential
indication of temperature and time) maintain the SET key pressed (long touch) until the
message [----].appears. When the Fahrenheit temperature scale is selected, the
clock acquires the 12h standard, and the AM and PM icons are used for time indication. In
this scale, the Time and Day messages of the parameter description are replaced by Time
and Day in the controller display.
5.6 EVENT SCHEDULE SETTINGS
To set the event schedule associated to the support outlet, you should hold the
4 seconds.
The schedule allows setting up to 4 events for each day of the week, as the programming
performed in parameter [,F11] - Filtering events schedule operating mode. Each event
is comprised by a final and initial schedule.
The event schedule gets factory settings in mode [,1t7], same events for each day of
the week, and the schedules are defined as follows:
Initial time for the
End time for the
1st event
1st event
Initial time for the
End time for the
4st event
4st event
If it is not necessary to use all 4 events, you should set these in the turned off state, by just
increasing the final time until [,OFF]appears. It is possible to set an event that begins in
one day and finishes in another. To do so you should raise the final event time until
[,CRo]appears and set on the following day the initial event with time on [00: 0 0].
According to the set operation mode, the following programming possibilities may be
presented:
Programmed case [,F11] = [,1B1]
2 seconds
Hold for
am pm
4 sec.
Preferential
Weekly
indication
programming
SET
1 second
Long touch
F
key. Through
Initial time for the
End time for the
2st event
2st event
Initial time for the
End time for the
3st event
3st event
Sunday
SET
Short touch
Monday
SET
Long touch
Tuesday
Wednesday
Thursday
am pm
Friday
am pm
Saturday
Programmed case
Hold for
am pm
4 sec.
Preferential
indication
1 second
Programmed case [,F11] = [,1T7]
Hold for
am pm
4 sec.
Preferential
indication
1 second
5.7 VIEW OTHER TEMPERATURES
To switch the temperature display of sensor T1, sensor T2 or the differential sensor (T1-
T2) give short touches on the key until the desired temperature is displayed. In the upper
display numbers the temperature measure is presented and in the lower display numbers,
the sensor description. The selected temperature will be displayed during 10 seconds.
After, which the preferential indication is again displayed, as set in parameter [,F01] –
Preferential Indication.
5.8 FUNCTION BLOCK
For security reasons and in order to avoid unauthorized people changing the controller
settings, there is the function block resource. With that setting activated, the parameters
cannot be changed, but they can be displayed, however. In the block condition, upon trying
key for
to change the value of a parameter the message ''[,LOC][,,ON]no display" will be
displayed.
To enable/disable the function block you should hold the key for the time set in parameter
[,F14]
– Time for function block. The icon
it is accessed, it indicates that the function block is active.
HINT: with active function block one avoids that children, visitors or curious people change
the operation mode or the controller parameters. When some change is needed, just hold
the key to enable/disable this resource.
6. ADVANCED OPERATIONS FOR THE INSTALLER (TECHNICAL USE)
6.1 CONTROLLER PARAMETERS CHANGE
Access the settings menu holding the SET key for 4 seconds until [FuNc] appears.
After that [Code] will appear and then press once again the SET key, short touch. Use
the or keys to enter the access code value, 123, and when ready press the SET key
once again (short touch).
or keys to select the desired function. With a short touch to the SET key it's
Use the
possible to edit its value. Use the
short touch on the SET key to memorize the set value and return to the function menu.
To leave the menu and return to normal operation (temperature indication) hold the SET
key (long touch) until [----] appears.
Observations:
SET
- Upon accessing the parameter settings, the upper display will flash and over
it the SET icon is displayed, indicating that it is possible to change the
parameter value.
LOC
- If the 123 code has not been inserted, upon accessing the parameter settings
the icon
SET
setting is locked.
Short touch
Adjustment
LOC
- With active function block, upon pressing the
SET
Short touch
function value, the controller will display the [,LOC][,,On]message on
Adjustment
am pm
the screen and it won't be possible to perform the parameter setting.
SET
Short touch
Adjustment
SET
Short touch
Adjustment
[,F11]
= [,2T6]
2 seconds
Sunday
am pm
Weekday
Programming
Weekdays
am pm
SET
Long touch
Saturday
SET
2 seconds
Short touch
Adjustment
Daily
programming
SET
Short touch
Adjustment
SET
Long touch
SET
Short touch
Adjustment
SET
Short touch
Adjustment
indicates the block state to the user, in case
or keys to change the value, and when ready give a
LOC
will be displayed over the upper display, indicating that the
SET
Short touch
SET
Adjustment
Short touch
SET
SET
Long touch
Short touch
Adjustment
SET
Short touch
Adjustment
SET
Short touch
Adjustment
or
keys to change the

Advertisement

loading
Need help?

Need help?

Do you have a question about the Microsol FLT Advanced and is the answer not in the manual?