DURKOPP ADLER M-TYPE DELTA D867 Additional Instructions page 10

Electropneumatic needle cooling
Hide thumbs Also See for M-TYPE DELTA D867:
Table of Contents

Advertisement

Fig. 5: Assembling the needle cooling (5)
(15) - Hose
(16) - Hole
19. Slide the block (17) with blow tube (18) and hose (15) onto the walking
20. Assemble the walking foot (13).
21. Insert the needle (14).
22. Align the blow tube (18) with the needle so that the blow tube (18) is
Important
Turn the handwheel and check if the blow tube (18) collides with the finger
guard.
If necessary, slightly correct the position of the blow tube (18).
23. Lay the hose (15) towards the rear to the stepper motor using cable
24. Feed the hose (15) towards the front through the hole (16) in the
8
foot bar.
at the center relative to the needle eye.
clamps.
machine casting.
Needle cooling from above
(17) - Block
(18) - Blow tube
Additional Instructions D867 - 01.0 - 04/2020

Advertisement

Table of Contents
loading

Table of Contents