INSP
ADJ
a
3160
OIL INJECTION SYSTEM
1
3150
2
3
SYNCHRONIZING THE OIL PUMP
1. Check:
• Oil pump lever position
Incorrect → Adjust.
NOTE:
Make sure the oil pump lever 1 touches the
stopper a (fully closed position) when the
throttle valves are closed.
2. Adjust:
• Oil pump lever position
Adjustment steps
(1) Loosen the locknut 2.
(2) Remove the clip and washer.
(3) Disconnect the oil pump link rod joint
3.
(4) Fully close the throttle valves.
1
(5) Turn the oil pump lever 1 so it con-
tacts the stopper a (fully closed posi-
tion).
(6) Adjust the position of the oil pump link
rod joint until its hole aligns with the
set pin on the oil pump lever 1.
(7) Install the washer and clip.
(8) Tighten the locknut.
CAUTION:
After adjustment, make sure the oil pump
lever operates properly.
3-13
E
3