Mitsubishi Heavy Industries FDT100VNAWVH Service Manual page 32

Micro inverter packaged air-conditioners (split system, air to air heat pump type)
Table of Contents

Advertisement

(i) Power saving / comfort control
The set temperature is adjusted according to the presence of people and their amount of activity detected by the infrared (motion)
sensor.
MODE:AUTO/COOL/HEAT mode operation
Heat Source & Activity
COOL
Set
temperature
HEAT
Notes (1) When the following operations are set, power saving control will be canceled.
① Energy-saving, Home leave mode, Warm-up control, Cooling operation check.
② When the operation mode is changed DRY or FAN.
(2) Not operable while the air-conditioner is OFF.
(ii) Auto-off control
When no activity is detected for 1 hour, unit will go stand-by mode.
original set temperature by activity detection during the stand-by mode. When stand-by mode continues for 12 hours,
unit stops.
※ Compressor keeps stopped regardless of the set temperature.
Low
High
Normal
+3ºC
31
-
-
None
Low
33ºC
High
None
When the "None" continues for 1 hour, the
-3ºC
FAN SPEED is set Lo.
15ºC
Unit will re-start operation automatically with the
'19 • PAC-SM-309
When the extent of human
activity is low
When the extent of human
activity is high
When there is no one in the
room

Hide quick links: