Water Pump; Bypass Manifold - Prochem BLAZER PLUS Operating Instructions Manual

Mobile cleaning unit
Table of Contents

Advertisement

WATER PUMP

Refer to the Water Pump Operation and Service
Manual for specific instructions.
1. Check the crankcase oil level daily to assure the
proper level. If the level has dropped, check for
the source of leakage and repair.
2. Change the crankcase oil with Cat Pump
Crankcase Oil, Part #05-008016, after the first
50 hours of operation. Drain and refill the
crankcase oil with Cat Pump Crankcase Oil
every 500 hours thereafter.
VACUUM INLET FILTER
(IN WASTE TANK)
1. The vacuum filter in the waste tank should be
removed and cleaned daily. If this is done, the
filter will last for a long period of time.
2. Replace this filter at least once per year.
When removing the vacuum inlet filter, grip the
plastic hexagonal section of filter. Grasping filter
by the screen may collapse or ruin the filter.
NOTE: When replacing this filter, we
recommend using a stainless steel PROCHEM
filter (#14-806518) only. This will prevent rust and
corrosion from entering the vacuum system.
WASTE TANK STRAINER BASKET
The strainer basket located inside the waste tank
should be removed and cleaned whenever it is full of
debris. This should be done on at least a daily
basis.

BYPASS MANIFOLD

(STRAINER AND JET BLOCK)
Check the strainer and the jet weekly. Remove any
debris or blockage.
For the procedure, see the "General Service
Adjustments" section in this manual for details.
BLAZER 980073 09/16/02
MAINTENANCE