REMOVING ANTI–FREEZE FROM THE
UNIT
:
1. Connect one end of the loop hose to the solution
outlet connection. Place the other end of the
loop hose, without the attachment, into an
approved container.
2. Start the unit. Allow the anti-freeze to flow into
the container until the pressure begins to drop
on the pressure gauge. Then shut-down the unit.
3. Fill the water box with fresh water and repeat
step #2.
4. Connect the water inlet hose to the water inlet
connection on the console. Turn the water
supply on.
5. Connect all solution hoses and any tools which
require purging of anti-freeze to the solution
outlet connection.
6. Open the tool valve and drain the anti-freeze
into an approved container until the flow is clear
and all anti-freeze is purged from the tools and
hoses.
7. Place the chemical prime hose into the
approved container. Submerge the chemical
inlet hose in water. Turn the chemical valve to
the PRIME position until clear water comes
through the prime hose, and then remove the
prime hose from the container.
Turn the chemical valve to the ON position. This
will allow water to flow into the other side of the
system.
Once all of the anti-freeze is removed, the unit is
ready to use.
Eventually, the anti-freeze in your storage
container will become diluted with water. If the
anti-freeze level drops below 50% of the total,
dispose of it and start with fresh 100% anti-
freeze.
freeze, observe local laws and regulations.
Where permitted, we recommend disposal in
sanitary sewer systems. Do not drain onto the
ground or into storm drainage systems.
BLAZER 980073 09/16/02
When disposing of used anti-
WINTERIZING LOOP
HOSE ASSEMBLY
LOOP HOSE
ATTACHMENT