Micro-Mist SURFACE DISINFECTING SYSTEM SAFETY, OPERATION & MAINTENANCE INSTRUCTIONS MODELS: MICRO-MIST M500 • CAUTION – READ THE INSTRUCTION MANUAL BEFORE USING THE APPLIANCE • ORIGINAL INSTRUCTIONS • MANUAL ALSO AVAILABLE ON LINE AT WWW.PROCHEM.CO.UK Page 1 of 25 Micro-Mist Manual 07/20...
Page 2
All information and specifications in this manual are current at the date of issue. However, because of Prochem Europe policy of continual product improvement, we reserve the right to make changes at any time without notice. Please note that this manual applies to all models and explains variations including accessories used.
CONTENTS PAGE NO. WARRANTY WARNING SECTION IMPORTANT SAFETY INSTRUCTIONS GENERAL DESCRIPTION OF APPLIANCE & IMPORTANT OPERATING INSTRUCTIONS GENERAL OPERATING INSTRUCTIONS UNDERSTANDING YOUR MICRO-MIST UNIT CHEMICALS OPERATING INSTRUCTIONS GENERAL MAINTENANCE TROUBLESHOOTING SECTION MACHINE PARTS DIAGRAM & PARTS LIST MISTING GUN PARTS LIST WIRING DIAGRAM CE DECLARATION OF CONFORMITY Page 3 of 25...
Page 4
Prochem Europe Sales Department Telephone: +44 (0)20 8974 1515 Prochem Europe Ltd. EEE Producer Registration Number: WEE / AJ0044SY European Directive (2011/65/EU) Restriction of use of certain Hazardous Substances in Electrical and Electronic Equipment (RoHS2).
Your Prochem unit is designed to give you many years of reliable service. If a problem should arise during or after the warranty period, contact the Prochem Authorised Distributor or the Prochem Service Department, for details of the services available. Only the original purchaser of the new equipment may seek performance of this warranty –...
WARNING! • Warning! Machines shall not be used by children. Children should be supervised to ensure that they do not play with the appliance. This machine can be used by people with reduced physical, sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction concerning the use of the machine in a safe way and understand the hazards involved.
Please read this manual hoses. carefully and obtain operating instruction from your Prochem Distributor or authorised representative in !! DO NOT use this machine with or near flammable the correct use of this equipment and suitable vapours. These machines can ignite flammable chemicals before attempting to clean.
GENERAL DESCRIPTION OF APPLIANCE The Micro-Mist Machine is a surface disinfecting spray unit for use with Prochem D500 Microsan® and B125 Clensan®. The machine incorporates a solution hose assembly and a misting gun. The machine has a disinfectant solution tank and a caddy for the storage of solution containers and PPE.
Prochem. • All repairs must be carried out by an authorised Prochem machines have been designed with the Prochem distributor. operator in mind. Provided you read the instructions relating to the care of your machine and •...
UNDERSTANDING YOUR MICRO-MIST UNIT. OVERVIEW The Micro-Mist machine has only one mechanical part, this is a 220psi 230V DC drive Diaphragm pump. The pump is operated by a switch on the main body of machine close to the main solution outlet. The pump forces a pressurized solution from the solution tank via a high-pressure solution hose and a misting gun to the surface being disinfected.
Page 11
Item Description Number Handle Storage Compartment Solution Tank Access Misting Gun holster Bracket Pump Power Switch Blank Switch Cover Power Cord Pressure Outlet Page 11 of 25 Micro-Mist Manual 07/20...
CHEMICALS Prochem specialize in the manufacture of chemical products for use on soft furnishings and hard surfaces, this section deals with the products recommended for use with the Micro-Mist unit. Prochem D500 Microsan® Concentrate Product Description & Directions for Use: A multi-surface biocidal cleaning concentrate for hard surfaces, floors, carpets and upholstery.
The machine must be used in an upright condition on a flat and level surface OPERATING INSTRUCTIONS Important: Use only the Prochem misting gun supplied with the Micro-Mist unit. It is designed to deliver and maintain the correct amount of solution and pressure when attached to the Micro-Mist pump system.
GENERAL MAINTENANCE All Prochem machines are engineered and built to require a minimum of maintenance. But like any machine, it does require some care to keep it in optimum working condition. Careful attention to these maintenance instructions will give you maximum operating performance and will increase the life expectancy of the machine.
Page 15
The pump motor brushes should be inspected for motor brush wear every 6 months for heavy usage and 12 months for normal usage. In the event of a reduction in operating pressure, leakage or pump failure refer to the “Fault Finding Guide” And contact your Prochem distributor. Page 15 of 25 Micro-Mist Manual 07/20...
MISTING GUN PARTS LIST AC9000-2 REF. STOCK CODE PART NO. DESCRIPTION GU00102 A00102 QUICK DISCONNECT, .25” F, .25” FP, BRASS E12964 A12964 COUPLER, .25”, BRASS A13775 HEX NIPPLE, .375” X .250 A14779 ATOMIZING TIP, TN2 QUICK CHANGE BODY A14780 A14781 QUICK CHANGE CAP (PART OF KIT TO INCLUDE ITEM 7) A14781 GASKET, QUICK CHANGE TIP (PART OF KIT TO INCLUDE ITEM 6)