If there is a lack of interior Heat:
Note:
The 120 Volt-AC Electric Heating Element is the
Aqua-Hot's secondary heat source for heating both the
interior and/or the domestic hot water during low heating
demand situations (such as when moderate ambient tem-
peratures exist and/or when there is a low demand for
domestic hot water). If the ambient temperature is ex-
tremely cold the Burner must be utilized.
1. Is the Burner activated?
2. Is the Burner operating Properly?
3. What is the antifreeze concentration, inside of the Aqua-
Hot Boiler Tank?
4. If the LTCO light is not illuminated on the Electronic Con-
troller check the following:
- Is the heater up to operating temperature?
- Is there a hot water faucet/fitting leaking?
- Is there fresh water in the motor home?
5. Was the heating system properly installed, following the
400LP installation manual?
- Are there at least 5 heat exchangers installed in the
interior of the motor home?
- Are there cold air returns installed for every heat
exchanger? Reference Figure B2.
- Are the heat exchangers mounted as close to the hot
air outlet grill as possible? Reference Figure B2.
Figure B-3
Figure B-2
© Aqua-Hot® AHE-400-P01 Service Manual Rev.B June 2014