Control Thermostat - Aqua-Hot 400 Series Service Manual

Hide thumbs Also See for 400 Series:
Table of Contents

Advertisement

Control Thermostat Replacement Procedure:
Failure to disconnect all power supplies and/or to allow the
heater to cool before servicing could cause serious damage
or personal injury
1. Ensure that the Aqua-hot has been completely shut
down and all power sources have been disconnected.
Also, because this replacement procedure will involve
the boiler tank and the potential for hot coolant, be sure
the heater has adequately cooled.
2. Drain the antifreeze and water heating solution from
the Aqua-Hot's boiler tank using the drain valve.
3. Disconnect the defective control thermostat's wires by
separating the quick disconnect terminals.
Thermostats
Figure 12
4. Using a 7/8" socket, unscrew the control thermostat
from the Aqua-Hot's boiler tank.
5. Wrap the threads of the replacement control thermostat
with 6 wraps of a thread seal tape.
6. Screw the replacement control thermostat into the port
on the Aqua-Hot's boiler tank and tighten securely with
a 7/8" socket.
7. Connect the replacement control thermostat's wires in
the same configuration as the removed control thermo-
stat's wires.
8. Refill the Aqua-Hot's boiler tank with the antifreeze and
water heating solution.
9. Test the Aqua-Hot for normal operation.

Control Thermostat

© Aqua-Hot® AHE-400-P01 Service Manual Rev.B June 2014