Only the arrow on the B side shows. An object crossing a configured line in both directions
can be detected and trigger alarms.
A->B
Only an object crossing the configured line from the A side to the B side can be detected.
B->A
Only an object crossing the configured line from the B side to the A side can be detected.
3) Set Sensitivity. The higher the value is, the easier the detection alarm will be triggered.
4) Click Draw Area, and set two points in the preview window to draw a virtual line.
4. Set the arming schedule. Refer to for Configure Arming Schedule details.
5. Set the linkage actions. Refer to Configure Alarm Linkage Action for details.
6. Click Apply.
Configure Arming Schedule
Steps
1. Select Arming Schedule.
2. Choose one day of a week and set the time segment. Up to eight time periods can be set within
each day.
Note
Time periods shall not be repeated or overlapped.
3. Click Apply.
Configure Alarm Linkage Action
Alarm linkage actions will be activated when an alarm or exception occurs.
Digital Video Recorder User Manual
Figure 5-12 Set Arming Schedule