1-4 Assembly and Disassembly
1-4-1

Precautions for assembly and disassembly

(1) Precautions
Be sure to turn the power switch of the machine off and disconnect the power cable before starting disassembly of the
paper feeder. For the multi purpose feeder, remove also the power cord/junction cable (refer to the figure below).
When handling PWBs, do not touch connectors with bare hands or damage the PWB.
Do not touch any PWB containing ICs with bare hands or any object prone to static charge.
When removing the hook of the connector, be sure to release the hook.
Take care not to get the wire caught.
Multi purpose feeder
Power cord/
Junction cable
Figure 1-4-1
Junction cable
3K8/3K9
1-4-1