ELECTRICAL
1. Connect the appliances power cord to the transformers
output.
2. Plug the transformer into an electrical outlet.
PRESSURIZING
1. Put the bypass system in 'bypass' position.
2. Make sure the electronic controller of the appliance is in
service mode.
3. Open the mains water supply.
4. Open a cold treated water faucet nearby the appliance
and let the water run for a few minutes until all air is
purged and all foreign material that may have resulted
from the installation is washed out; close the tap.
5. Gently pressurize the appliance, by putting it into service:
close the 'BYPASS' valve;
open the 'OUT' valve;
slowly open the 'IN' valve.
6. After 2-3 minutes, open a cold treated water faucet
nearby the appliance and let the water run for a few
minutes until all air is purged from the installation and the
filter media is rinsed (it is normal for the rinse water to
show some discoloration!); let the water run until the
rinse water is clear; close the tap.
7. Check the appliance and all hydraulic connections for
leaks.
During the passage through the compressed air
chamber, the treated water will get highly oxygenated. As a
consequence it may become slightly non-transparent (milky
appearance) when it flows from the tap into a glass. This is
totally harmless for the quality of the treated water and will
disappear rapidly if the water is left standing for a moment!
ELECTRONIC CONTROL PANEL
1. Program the electronic controller.
INITIATE A REGENERATION
We strongly recommend to postpone the execution of
this 'start-up' regeneration by 24 hours. The filter media
needs sufficient time to absorb water and reach its normal
service weight. If the regeneration is performed too soon,
the filter media may be pushed against the top distributor
during the backwash cycle, possibly resulting in loss of filter
media or damage to the top distributor.
1.
Manually initiate a regeneration, by pressing the scroll
button repeatedly until the display shows:
Regen in 10 sec
2. Leave the appliance in this position; the count-down
timer will count down to 0 sec and start a regeneration.