How To Install The Indoor Unit; Starting The Installation; How To Make A Hole - Panasonic S-45MK2E5A Installation Instructions Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

3. HOW TO INSTALL THE INDOOR UNIT

3-1. Starting the Installation

(1) Remove the rear panel.
NOTE
Tubing can be extended in 6 directions as shown below.
Select the direction you need providing the shortest run to the outside unit.
Tubing direction
Left tubing
Left-downward tubing

3-2. How to Make a Hole

The mounting wall should be strong and solid enough to withstand the unit's vibration.
(1) Place the installation plate from the indoor unit on the wall at the location selected.
Wall
132.5
ø80 Hole for left side tubing
* Mount the installation plate with 5 screws completely.
Dimension
1
2
3
607.5
612
105
Make sure the installation plate is horizontal, using a carpenter's level or tape measure to measure down from the ceiling.
Wait until after cutting the hole before attaching the installation plate to the wall.
* The center of installation plate should be at more than 1 at right of the wall.
* The center of installation plate should be at more than 2 at left of the wall.
* The distance from installation plate edge to ceiling should be more than 3.
* From installation plate left side to unit's left side is 4.
* From installation plate right side to unit's right side is 5.
* For left side tubing, tubing connection for liquid should be about 6 from this line.
* For left side tubing, tubing connection for gas should be about 7 from this line.
Left-rear
tubing
Right-downward tubing
More than 1
4
128
6
7
unit: mm
4
5
6
183.5
188.5
400
Right-rear tubing
Right tubing
Ceiling
More than 3
More than 2
Gas tube
Liquid tube
ø80 Hole for right side tubing
7
450
8
Wall
5
128
137.5

Hide quick links: