Fluid Line Accessories
Install the following accessories in the locations shown
in Fig. 4, using adapters as necessary:
D
A fluid filter (L) with a 60 mesh (250 micron)
stainless steel element, to filter particles from the
fluid as it leaves the pump.
D
A fluid drain valve (M), which is required in your
system, helps relieve fluid pressure in the hose
and gun (see the WARNING on page 7).
TYPICAL HYDRAULIC-POWERED INSTALLATION
KEY
A
Pump
B
Wall Bracket
C
Hydraulic Supply Line
D
Hydraulic Return Line
E
Drain Line (from pressure reducing valve)
F
Pressure Gauge
G Flow Control Valve
H
Pressure Reducing Valve
J
Accumulator
K
Drain Line (from motor drip pan)
L
Fluid Filter
M Fluid Drain Valve (required)
N
Electrically Conductive
Fluid Supply Hose
P
Fluid Whip Hose
R
Gun Swivel
S
Airless Spray Gun
T
Drum Suction Kit
U
Hydraulic Supply Line Shutoff Valve
V
Hydraulic Return Line Shutoff Valve
Y
Ground Wire (required, see page 6 for
installation instructions)
AA Hydraulic Return Line Filter
HYDRAULIC
POWER SUPPLY
Fig. 4
Installation
(HYDRAULIC-POWERED PUMPS)
J
H
F
E
U
G
C
D
AA
DRAINAGE
CONTAINER
D
A gun (S) dispenses the fluid. The gun shown in
Fig. 4 is an airless spray gun for light to medium
viscosity fluids.
D
A gun swivel (R) allows freer gun movement.
D
A suction kit (T) allows the pump to draw fluid
from a supply container.
V
A
Y
L
B
M
K
200 LITER (55 GAL.)
DRUM
S
R
P
N
T