Srx1400 Services Gateway Dc Power Supply - Juniper SRX1400 Hardware Manual

Services gateway
Hide thumbs Also See for SRX1400:
Table of Contents

Advertisement

Table 20: AC Power Supply LEDs (continued)
Color
Status
Amber
On steadily
Blinking
RELATED DOCUMENTATION
SRX1400 Services Gateway Power Supplies Overview | 57
Installing an AC Power Supply in the SRX1400 Services Gateway | 136
Maintaining Power Supplies on the SRX1400 Services Gateway | 178
Troubleshooting the Power System on the SRX1400 Services Gateway | 186

SRX1400 Services Gateway DC Power Supply

IN THIS SECTION
DC Power Supply Overview | 61
DC Power Supply Electrical Specifications | 61
DC Power Supply LEDs | 61
This topic includes the following sections:
Condition Indicated
The power supply has detected one or more of the following faults:
Power supply fan failure
Power supply over-temperature condition
Over-current or under-voltage condition on the standby 3.3 V output
The power supply has detected one or more of the following faults:
Under-voltage condition on the 12 V output
Over-voltage condition on the 12 V output
Over-current condition on the 12 V output