Installation; Mounting - Graco InvisiPac GM100 Plug-Free Instructions Manual

Hot melt applicator
Table of Contents

Advertisement

Installation

Installation

Mounting

To prevent heat transferring into other components of
the packaging line, ensure that the insulator is
installed
Low Profile Models: Use a 3/4 in. (19 mm) wrench to
adjust the nuts that control the position of the applicator
on the threaded rod.
All Other Models: See Figure 3 and the following
instructions. Mount the manifold on to a 1/2 in. (12 mm)
diameter bar using the mounting clamp (H) to hold the
applicator in place and ensure adhesive is applied
properly. For optimal mounting strength of a slim model,
use a 7/16 hex bar.
NOTE: Slim, standard dual, and standard quad models
use a 5 mm Allen wrench.
1. Remove the solenoid. For removal and installation
instructions, see Replace Solenoid Valve on page
23.
F
. 3
IG
8
NOTICE
2. Remove the existing clamp and replace the bottom
part with the new clamp A.
3. Before mounting to the rod, loosely thread screw C
into block A and thread screw D through block B into
the assembly.
4. Hold the applicator up to the 1/2 in. diameter bar
and rotate the top clamp B so that the screw C
moves into the slot.
5. Use a 3 mm Allen wrench to torque screw C and a 5
mm Allen wrench to torque screw D.
6. Re-install the solenoid.
Connect Heated Hose
1. Connect the hose fluid outlet to the manifold fluid
inlet (E). Use two 11/16 in. wrenches to tighten the
hose fitting.
F
. 4
IG
2. Connect the cordset (F) to the hose.
3. Connect the hose inlet to the melter system outlet.
Refer to the InvisiPac Heated Hose Instructions for
installation guidelines. See Related Manuals on
page 3.
4. Connect the hose cordset to the melter. Refer to the
InvisiPac Heated Hose Instructions for installation
guidelines. See Related Manuals on page 3.
334627K