Replace Applicator - Graco InvisiPac GM100 Plug-Free Instructions Manual

Hot melt applicator
Table of Contents

Advertisement

Repair
5. Hold a rag over the manifold air ports and turn the
air supply ON to clean the ports as shown in Figure
19.
F
. 19
IG
6. Cycle the solenoid by pushing the blue button on the
solenoid.
7. Turn off the air supply and remove the rag.
8. Apply the high-temperature lubricant to the air
section o-rings (2b) and the fluid section o-ring (2a)
in the module (2).
NOTE: The air section o-rings are brown and the fluid
section o-ring is black. All o-rings are fluoroelastomer.
The color is only used to identify the difference in size.
9. Apply anti-seize to the two screw threads (22). Use
a 3 mm Allen wrench to install the new module (2)
on the manifold with the two screws (22). Torque to
28-32 in-lb (3.2-3.6 N•m).
10. Connect the cordset (17) to the heated hose.
24

Replace Applicator

1. Disable the applicator. See Before Beginning
Repair on page 19.
2. Loosen the mounting bar clamp and remove the
applicator from the mounting bar.
3. Install the new applicator. See Installation on page
8.
334627K

Advertisement

Table of Contents
loading