Download Print this page

Pentair EasyTouch Installation Manual page 10

Upgrade to intellicenter control system
Hide thumbs Also See for EasyTouch:

Advertisement

4
Removing the Existing Outdoor Control Panel
The following upgrade installation instructions are for EasyTouch
Control Systems using the 2012 or later (square low voltage circuit breakers configuration on bezel) Load
Center or Power Center.
RISK OF ELECTRICAL SHOCK. BEFORE REMOVING THE HIGH VOLTAGE
MAIN POWER AT THE HOME AT THE MAIN CIRCUIT BREAKER BOX.
1. TURN OFF POWER TO ALL POOL AND SPA EQUIPMENT BEFORE STARTING.
CAUTION! DO NOT PLUG IN OR UNPLUG ANY SYSTEM COMPONENTS WITH THE
POWER ON. THIS MAY DAMAGE THE SYSTEM COMPONENTS.
2. Unlatch the front door latch. Open the door of the Load Center or Power Center.
3. Remove the two screws securing the High Voltage Cover Panel. Remove the panel and set
aside.
4. Loosen the two retaining screws securing the existing control panel. Fold down the panel to
access the circuit board low voltage connections and transformer connector.
Continue to next page
Retaining screw
Bezel screw
Figure 2. Load Center or Power Center (2012 or later)
Note: Refer to page 3 where (parts index number) is shown
COVER PANEL FROM THE ENCLOSURE SWITCH OFF THE
Front
door
EasyTouch/IntelliTouch Control System Upgrade Kits Installation Guide
PL4/PSL4, EasyTouch or IntelliTouch
®
WARNING!
Three Tabs/Slots
Retaining screws
(for High Voltage Cover
Panel)
High Voltage
Cover Panel
Retaining screw
Bezel screw