INSTALLATION: INDOOR UNIT
Dimension Drawing of Indoor Unit Installation
Mounting Plate
1. The wall for installation of the indoor unit
shall be hard and firm, so as to prevent
vibration.
2. Use the "+" type screw to fasten the peg
board. Horizontally mount the peg board
on the wall and ensure the lateral
horizontal and longitudinal vertical.
3. Pull the peg board by hand after the
installation, to confirm whether it is solid.
Wall-through Hole
1. Make a hole with an electric hammer or a
water drill at the predetermined position
on the wall for piping, which shall slant
outwardly by 41°F-50°F.
2. To protect the piping and the cables from
being damaged running through the wall,
and from the rodents that may inhabit in
the hollow wall, a pipe protecting ring
shall be installed and sealed with putty.
NOTE: Usually, the wall hole is 60mm ~
80mm. Avoid pre-buried power wire and
hard wall when making this hole.