Test Operation; Notices For Use - Royal Sovereign RSAC-1217S Operating Manual

Mini-split air conditioner
Table of Contents

Advertisement

TEST OPERATION

Test Operation Preparation
• Verify that all piping and connection cables are well connected.
• Confirm that the values at the gas side the liquid-side are fully open.
• Connect the power cord to an independent power socket.
• Install batteries in remote control.
Test Operation Method
1. Turn on the power and push the ON/OFF switch button of the remote
controller to start the air conditioner.
2. Select COOL, HEAT (not available on cool-only models), SWING and other
operation modes with the remote controller and see if the operation is ok.
Specific Caution
1. Open the front panel of the indoor.
2. The connector can not touch the
terminal board, and is positioned as
shown in the picture to the right.

NOTICES FOR USE

The Conditions of Unit Can't Normally Run
• Within the temperature range provided in following table, the air conditioner
may stop running and other anomalies may arise.
• When the temperature is too high, the air conditioner may activate the
automatic protection device, so that the air conditioner could be shut down.
• When the temperature is too low, the heat exchanger of the air conditioner
may freeze, leading to water leakage or other malfunction.
• In long-term cooling or dehumidification with a relative humidity of above
80% (doors and windows are open), there may be water condenses or
dripping near the air outlet.
• T1 and T3 refer to ISO 5151.
16