 Insert the accompanying hose at the
hose connection of the surface cleaner
and secure it by turning.
 Route the other end of the hose to a
drain and secure it by means of the ac-
companying hook-and-loop tape.
Note:
If possible, lay hose without any slopes.
Maximum delivery height of the waste wa-
ter is 1 m.
The free end of the hose can be attached
by means of the included Velcro tape (e.g.
on a drain grid).
If necessary, use extension hose (see "Ac-
cessories").
 Hold the trigger gun and the handle of
the surface cleaner firmly with both
hands.
 Guide the surface cleaner so that it re-
mains close to the surface to be
cleaned.

Shutting down

 After operation with hot water, operate
the surface cleaner with cold water for
two minutes to cool it down.
 If necessary, rinse the surface cleaner
and the suction hose with clear water.
 Protect the appliance against frost.
 Do not allow bristles to deform during
storage.
Note:
In order to ensure a good suction result,
please do not place the surface cleaner
onto the brush crown after use.
 Rinse the steering rollers with clear wa-
ter after use and spray with creeping oil
after they have dried.
8
Care
Accessories
Accessories
Hose fastener (suction
cup to install on smooth
surfaces)
Dirt catcher (coarse dirt
separator)
Hose support (wall
mount)
Brush crown FR 50 ME 6.371-011.0
Extension hose

Troubleshooting

Rotation arm does not rotate:
 Check if the cleaning nozzles are dirty.
Vacuum performance decreasing:
 Bristle crown worn - replace bristle
crown.
 Suction channel/suction hose blocked -
clean suction channel and suction
hose.
 Injector nozzle blocked - clean the in-
jector nozzle.